Before installing the appliance, check that
¡
the local conditions of the supplier are
compatible with the appliance settings
specified on the rating plate (type of gas
and pressure, power, voltage).
Secure the power cord to the cabinet to
¡
prevent it from touching hot parts of the
oven or hob.
Before any work is carried out on the ap-
¡
pliance, switch off the power supply and
the gas supply.
Connect the appliance to the power sup-
¡
ply using the earth.
Do not make any changes to the inside of
¡
the appliance. If required, contact our
technical customer service.
Hong Kong town gas connection
External Gas Governor Maxitrol RV47LM-Rp 1/2",
provided with the appliance, must be installed.
Attention
According to the Gas Safety Ordinance of Hong
Kong, any gas installation works including the install-
ation of appliances and connection tubing, must be
undertaken by registered gas installers who are re-
gistered for that appropriate classes and be em-
ployed by registered gas contractors, respecting all
applicable regulations, standards and the specifica-
tions of the local gas and electricity suppliers. Spe-
cial attention shall be paid to ventilation regulations.
Use approved gas tubing bearing EMSD approval
marking (such as: 機電工程署批准EMSD APPROVAL
GTXXXX) for connection to appliances, or other ap-
propriate methods accepted by EMSD.
Before installing
This appliance can be combined with other hobs
¡
of the same brand by using the connection ac-
cessory. See catalogue.
The unit in which the appliance is installed must
¡
be stable and secured appropriately.
The units in the vicinity of the appliance, the lamin-
¡
ated panels and the adhesive with which they are
secured must be made of non-flammable, heat-
resistant materials.
Do not install this appliance above refrigerators,
¡
washing machines, dishwashers or similar.
The appliance must only be installed on an oven
¡
with forced ventilation. Check the dimensions of
the oven in the installation instructions for the
oven.
If you install an oven underneath the hob, the work
¡
surface thickness may differ from the dimensions
given in these instructions. Take note of the in-
formation in the oven installation instructions.
If you install an exhaust air fan or an extractor
¡
hood, refer to the installation instructions for these.
Always observe the minimum vertical distance to
the hob.
→ Fig.
1
Preparing the units
Make a cut-out in the worktop with the required di-
¡
mensions.
In recesses of 500 mm, the appliance must be in-
¡
stalled on the front edge of the recess. → "Posi-
tioning the appliance", Page 3
→ Fig.
2
Seal the cut surfaces of wooden work surfaces
¡
with a special glue seal to protect them from mois-
ture.
If there is no built-in oven underneath the hob, in-
¡
sert a non-flammable separator (e.g. metal or ply-
wood) at a distance of 10 mm from the hob. This
prevents access to the underside of the hob. The
distance from the intermediate floor to the mains
connection for the appliance must be at least 10
mm.
→ Fig.
3
Positioning the appliance
Note: Do not remove the adhesive seal fitted on the
lower edge of the hob. The adhesive seal prevents
the penetration of liquids.
Do not use silicone to bond the appliance to the
worktop.
Position the hob with the upper side facing down
1.
on a flat, stable surface.
Loosen the screws on the brackets so they can
2.
turn freely. You do not need to fully undo the
screws on the brackets.
→ Fig.
4
Turn the hob around and insert it into the recess.
3.
Insert the hob in the front of the recess.
→ Fig.
5
Turn the brackets and tighten them fully.
4.
→ Fig.
6
The position of the brackets depends on the work-
top thickness.
Removing the appliance
Disconnect the appliance from the electricity and
1.
gas connections.
Unscrew the brackets and proceed in reverse or-
2.
der.
Connecting the gas
Observe the country-specific guidelines.
CAUTION ‒ Risk of explosion!
A gas leakage may cause an explosion.
If any connection is handled, check the seal.
Arrange the gas connection so that the shut-off
¡
valve is accessible.
Ensure that the information on the rating plate re-
¡
garding the gas type and gas pressure complies
with the local connection conditions.
Connect the appliance to a fixed gas pipe or a
¡
flexible metal pipe.
The flexible metal pipe must not come into contact
¡
with the moving parts of the unit in which the ap-
pliance is installed (e.g. a drawer) and must not
be routed through any spaces which might be-
come obstructed.
Gas connection on the appliance: G 1/2.
¡
Hong Kong town gas connection
External Gas Governor Maxitrol RV47LM-Rp 1/2",
provided with the appliance, must be installed.
Model
PRA3A6B70X
ER3A6AB70X
PRB3A6B70X
PRB3B6B70X
ER3A6BB70X
ER3B6BB70X
Spare parts for gas connection
You can obtain the gas connection parts from the
technical customer service.
Working pressure
11 mbar
8 mbar
3