Download Print this page

Cherry AKTIVE KEY AK-PMH21OS-F Series Instructions And Safety Information

Wireless medical mouse with touch scroll sensor

Advertisement

Available languages

Available languages

Quick Links

Instructions and Safety Information
AK-PMH21OS-F series
Wireless Medical Mouse with Touch Scroll Sensor
Quick Start:
1)
Insert the supplied batteries as marked inside the battery compartment.
2)
Close the battery cover and tighten the screws.
3)
Connect the USB-RF-Dongle to the USB port of your host PC.
4)
Start using the mouse after automatic driver installation has completed.
Delivery Content:
1x 2,4 GHz Wireless Mouse
1x Screwdriver
1x 2,4 GHz USB-RF-Dongle
1x User Instructions
2x non-rechargeable Batteries AAA (Alkali-Mangan)
Safety Note: The enclosed batteries must not be charged!
Manufacturer:
Active Key GmbH
Web:
www.activekey.de
Brunnenäcker 6
Phone:
+49(0)9241/48337-0
D-91257 Pegnitz
Fax:
+49(0)9241/48337-29
Email:
info@activekey.de
U.S. Responsible Party:
Cherry Americas LLC
Contact Person:
Ed Ferraton
5732 95th Ave.,
Phone:
+1 262-942-6393
Suite 850
Email:
ed.ferraton@cherryamericas.com
Kenosha, WI 53144,
Product Name:
Wireless Medical Mouse, USB-RF-Dongle
United States
Model Number(s):
HM803B, DON2
FCC ID:
2ACVU-HM803B, 2ACVU-D2
Specification:
2400 MHz – 2483,5 MHz
Frequency-band
Maximum transmission power
10 mW
Agency Approvals and Tests:
CE, RoHS, FCC, EN 60601-1-2:2015*
* No Medical Device acc.to Regulation (EU) 2017/745
Legal Information FCC:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
All rights reserved. Copy or duplication, except for personal use, not permissible without specific prior written consent by Active Key
GmbH. Contents are subject to change without notice. Errors excepted.
© Active Key GmbH; Version 20230402
Instructions and Safety Information
AK-PMH21OS-F series
Wireless Medical Mouse with Touch Scroll Sensor
Quick Start:
1)
Insert the supplied batteries as marked inside the battery compartment.
2)
Close the battery cover and tighten the screws.
3)
Connect the USB-RF-Dongle to the USB port of your host PC.
4)
Start using the mouse after automatic driver installation has completed.
Delivery Content:
1x 2,4 GHz Wireless Mouse
1x Screwdriver
1x 2,4 GHz USB-RF-Dongle
1x User Instructions
2x non-rechargeable Batteries AAA (Alkali-Mangan)
Safety Note: The enclosed batteries must not be charged!
Manufacturer:
Active Key GmbH
Web:
www.activekey.de
Brunnenäcker 6
Phone:
+49(0)9241/48337-0
D-91257 Pegnitz
Fax:
+49(0)9241/48337-29
Email:
info@activekey.de
U.S. Responsible Party:
Cherry Americas LLC
Contact Person:
Ed Ferraton
5732 95th Ave.,
Phone:
+1 262-942-6393
Suite 850
Email:
ed.ferraton@cherryamericas.com
Kenosha, WI 53144,
Product Name:
Wireless Medical Mouse, USB-RF-Dongle
United States
Model Number(s):
HM803B, DON2
FCC ID:
2ACVU-HM803B, 2ACVU-D2
Specification:
2400 MHz – 2483,5 MHz
Frequency-band
Maximum transmission power
10 mW
Agency Approvals and Tests:
CE, RoHS, FCC, EN 60601-1-2:2015*
* No Medical Device acc.to Regulation (EU) 2017/745
Legal Information FCC:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
All rights reserved. Copy or duplication, except for personal use, not permissible without specific prior written consent by Active Key
GmbH. Contents are subject to change without notice. Errors excepted.
© Active Key GmbH; Version 20230402
Legal information FCC (continued):
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-
Reorient or relocate the receiving antenna.
-
Increase the separation between the equipment and receiver.
-
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-
Consult the dealer or an experienced radio/TV technician for help.
Modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
Legal information CE:
Hereby Active Key GmbH declares that the type of radio equipment used with the product models
HM803B (Wireless Medical Mouse) and DON2 (USB-RF Dongle) complies with the RED 2014/53/EU
directive. The full text of the EU declaration of conformity is available at the following internet address:
https://www.activekey.de/ce-doc/CE_DOC_RED_2014-53-EU_AK-PMH21.pdf
As distributor of batteries, we have the following obligations under article 20 of directive 2006/66/EC:
1)
Batteries can be returned free of charge after use in shops selling batteries.
2)
End users are legally obliged to return used batteries.
3)
Manufacturers of batteries are required to mark batteries with symbol of the crossed-out wheeled
bin before placing them on the market for the first time.
The manufacturer of batteries shall label batteries containing more than 0.0005 % by mass of mercury,
more than 0.002 % by mass of cadmium or more than 0.004 % by mass of lead, before placing them on
the market for the first time with the chemical symbols of metals (Hg, Cd, Pb) in which the limit is
exceeded. The characters are to be applied below the symbol.
Electrical and electronic equipment (EEE) is marked with the symbol of the crossed-out
wheeled bin indicating the requirement not to dispose of waste electrical and electronic
equipment (WEEE) as unsorted municipal waste and to collect such WEEE separately.
Final users of WEEE from private households shall be able to return WEEE as per EU country local
regulations into established collection facilities free of charge. Please consult your municipal waste
department for detailed advice on separate collection of WEEE.
Legal information FCC (continued):
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-
Reorient or relocate the receiving antenna.
-
Increase the separation between the equipment and receiver.
-
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-
Consult the dealer or an experienced radio/TV technician for help.
Modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
Legal information CE:
Hereby Active Key GmbH declares that the type of radio equipment used with the product models
HM803B (Wireless Medical Mouse) and DON2 (USB-RF Dongle) complies with the RED 2014/53/EU
directive. The full text of the EU declaration of conformity is available at the following internet address:
https://www.activekey.de/ce-doc/CE_DOC_RED_2014-53-EU_AK-PMH21.pdf
As distributor of batteries, we have the following obligations under article 20 of directive 2006/66/EC:
1)
Batteries can be returned free of charge after use in shops selling batteries.
2)
End users are legally obliged to return used batteries.
3)
Manufacturers of batteries are required to mark batteries with symbol of the crossed-out wheeled
bin before placing them on the market for the first time.
The manufacturer of batteries shall label batteries containing more than 0.0005 % by mass of mercury,
more than 0.002 % by mass of cadmium or more than 0.004 % by mass of lead, before placing them on
the market for the first time with the chemical symbols of metals (Hg, Cd, Pb) in which the limit is
exceeded. The characters are to be applied below the symbol.
Electrical and electronic equipment (EEE) is marked with the symbol of the crossed-out
wheeled bin indicating the requirement not to dispose of waste electrical and electronic
equipment (WEEE) as unsorted municipal waste and to collect such WEEE separately.
Final users of WEEE from private households shall be able to return WEEE as per EU country local
regulations into established collection facilities free of charge. Please consult your municipal waste
department for detailed advice on separate collection of WEEE.
Frequently Asked Questions (FAQ):
Usage of Medical protective gloves!
We recommend the use of nitrile gloves instead of latex gloves in the operation of our products! This
reduces the risk of allergies and avoids yellowing of the product by abrasion of the latex.
How to determine the battery status?
1)
The low battery indicator LED is located at the bottom side next to the optical sensor.
2)
Press both mouse buttons at the same time to activate the low battery indicator LED.
3)
The LED will light in green to indicate a battery voltage > 2.2 V
4)
The LED will light in red to indicate a battery voltage <= 2.2 V. Please change batteries.
5)
The mouse operation stops at a battery level of 2 V.
How to operate Wireless Mouse and Keyboard via the same USB-RF-Dongle?
1)
Both Wireless Mouse series AK-PMH21OS-F and any Active Key Wireless Keyboard can
operate via one and the same USB-RF-Dongle!
The feature is only supported with dongle-model "DON2" which is provided with the AK-
2)
PMH21OS-F series.
3)
Please confirm the model-name of the dongle which is engraved on the metal part of the
dongle.
4)
Disconnect the USB-RF-Dongle of the Wireless Keyboard from your host PC and connect only
the USB-RF-Dongle of the Wireless Mouse.
5)
Use the key combination Fn & Esc to pair the Keyboard with the USB-RF-Dongle of the
Mouse.
How to pair a new USB-RF-Dongle with the mouse?
Note: This procedure is only required in case you received a new USB-RF-Dongle as a spare part in
case the dongle was lost or damaged!
1)
Remove the batteries from the mouse, remove the dongle from the computer.
2)
Connect the dongle with the computer.
3)
Install the batteries to the mouse. Place the mouse as close as possible to the dongle. Press
the middle button (inside the battery compartment) for one time and the battery indicator LED
will flash for 3 seconds.
4)
Test the mouse for function. If the pairing process was not successful, please repeat the
instructions from step 1). In case of problems please contact our customer services.
Packaging Recycling Information:
The packaging material used with this product can be recycled and is identified as PAP-20 and
LDPE-04. Please follow the rules of your local community on collection of packaging material.
Frequently Asked Questions (FAQ):
Usage of Medical protective gloves!
We recommend the use of nitrile gloves instead of latex gloves in the operation of our products! This
reduces the risk of allergies and avoids yellowing of the product by abrasion of the latex.
How to determine the battery status?
1)
The low battery indicator LED is located at the bottom side next to the optical sensor.
2)
Press both mouse buttons at the same time to activate the low battery indicator LED.
3)
The LED will light in green to indicate a battery voltage > 2.2 V
4)
The LED will light in red to indicate a battery voltage <= 2.2 V. Please change batteries.
5)
The mouse operation stops at a battery level of 2 V.
How to operate Wireless Mouse and Keyboard via the same USB-RF-Dongle?
1)
Both Wireless Mouse series AK-PMH21OS-F and any Active Key Wireless Keyboard can
operate via one and the same USB-RF-Dongle!
The feature is only supported with dongle-model "DON2" which is provided with the AK-
2)
PMH21OS-F series.
3)
Please confirm the model-name of the dongle which is engraved on the metal part of the
dongle.
4)
Disconnect the USB-RF-Dongle of the Wireless Keyboard from your host PC and connect only
the USB-RF-Dongle of the Wireless Mouse.
5)
Use the key combination Fn & Esc to pair the Keyboard with the USB-RF-Dongle of the
Mouse.
How to pair a new USB-RF-Dongle with the mouse?
Note: This procedure is only required in case you received a new USB-RF-Dongle as a spare part in
case the dongle was lost or damaged!
1)
Remove the batteries from the mouse, remove the dongle from the computer.
2)
Connect the dongle with the computer.
3)
Install the batteries to the mouse. Place the mouse as close as possible to the dongle. Press
the middle button (inside the battery compartment) for one time and the battery indicator LED
will flash for 3 seconds.
4)
Test the mouse for function. If the pairing process was not successful, please repeat the
instructions from step 1). In case of problems please contact our customer services.
Packaging Recycling Information:
The packaging material used with this product can be recycled and is identified as PAP-20 and
LDPE-04. Please follow the rules of your local community on collection of packaging material.

Advertisement

loading

Summary of Contents for Cherry AKTIVE KEY AK-PMH21OS-F Series

  • Page 1 U.S. Responsible Party: Batteries can be returned free of charge after use in shops selling batteries. Note: This procedure is only required in case you received a new USB-RF-Dongle as a spare part in Cherry Americas LLC Contact Person: Ed Ferraton End users are legally obliged to return used batteries.
  • Page 2 Gebrauchsanleitung und Rechtliche Hinweise: Häufig gestellte Fragen: Hiermit erklärt Active Key GmbH, dass der vorbezeichnete Funkanlagentyp mit den Produktmodellen Verwendung von medizinischen Handschuhen! Sicherheitsinformationen HM803B (Kabellose 2Hgienemaus) und DON2 (USB-Funkempfänger) der Richtlinie RED 2014/53/EU Wir empfehlen den Einsatz von Nitril- statt Latexhandschuhen bei der Bedienung unserer Produkte. entspricht.