Hitachi YUTAKI S80 R410A Series Installation And Operation Manual page 51

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

NOTE
The data corresponding to DHW tank heater is calculated in combination with the YUTAKI S80
domestic hot water tank accessory "DHWS(200/260)S-2.7H2E(-W)".
• The status of Harmonics for each model, regarding compliance with IEC 61000‑3‑2 and
IEC 61000‑3‑12, is as follows:
Equipment complying with IEC 61000‑3‑2
(*): Professional use
Equipment complying with IEC 61000‑3‑12
Installation restrictions may be applied by supply authorities in relation to harmonics
• Check to ensure that existing installation (main power switches, circuit breakers, wires,
connectors and wire terminals) already complies with the national and local regulations.
• The use of the DHW tank heater is disabled as factory setting. If it is desired to enable the
DHW tank heater operation during normal indoor unit operation, adjust the DSW4 pin 3 of the
PCB1 to the ON position and use the adequate protections. Refer to the section
connection"
for the detailed information.
PMEN0648 rev.0 - 03/2023
Status regarding compliance with
IEC 61000‑3‑2 and IEC 61000‑3‑12
Models
Split system
Indoor unit
YUTAKI S80
RWH‑4.0NFE
RWH‑5.0NFE
RWH‑6.0NFE
RWH‑4.0VNFE
RWH‑5.0VNFE
RWH‑6.0VNFE
RWH‑4.0VNFWE
RWH‑5.0VNFWE
RWH‑6.0VNFWE
RWH‑4.0NFWE
RWH‑5.0NFWE
RWH‑6.0NFWE
6
"6.2 Electrical
42

Advertisement

Table of Contents
loading

Table of Contents