Universal Inputs X51, X52, X55 - Siemens MCP 398C Manual

Machine control panel
Table of Contents

Advertisement

Additional override switch
Connector designation: X32
Connector type:
6.1.4

Universal inputs X51, X52, X55

Universal input X51
Connector designation:
Connector type:
Universal input X52
Connector designation: X52
Connector type:
Machine control panel: MCP 398C
Manual, 12/2017, A5E43199783B AA
Pin
Signal name
9
OV_SP2
10
OV_SP1
Male connector, 2 x 5-pin, according to IEC603-13 with coding
Pin
Signal name
1
-
2
-
3
M
4
-
5
P5
6
OV_ADD16
7
OV_ADD8
8
OV_ADD4
9
OV_ADD2
10
OV_ADD1
X51
Male connector, 4-pin
Pin
Signal name
1
KT1_IN
2
KT2_IN
3
KT3_IN
4
M
Male connector, 4-pin
Pin
Signal name
1
KT4_IN
2
KT5_IN
Type
I
Rotary switch position/value 2
I
Rotary switch position/value 1
Type
n.c.
n.c.
V
Ground
n.c.
V, O
Supply 5 V, max. 100 mA
I
Rotary switch position/value 16
I
Rotary switch position/value 8
I
Rotary switch position/value 4
I
Rotary switch position/value 2
I
Rotary switch position/value 1
Type
I
Customer key 1
I
Customer key 2
I
Customer key 3
V
Ground
Signal type
I
Customer key 4
I
Customer key 5
6.1 Pin assignment of the interfaces
Meaning
Meaning
Meaning
Meaning
Connecting
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents