INSTALLATION MANUAL
AIR CONDITIONER (SPLIT TYPE)
Indoor unit
RAS-B05, 07, 10, 13, 16J2KVG-E
RAS-18J2KVG-E
Outdoor unit
RAS-05, 07, 10, 13, 16, 18J2AVG-E
R32 or R410A
ENGLISH
1122950196

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAS-18J2KVG-E

  • Page 1 R32 or R410A ENGLISH INSTALLATION MANUAL AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-B05, 07, 10, 13, 16J2KVG-E RAS-18J2KVG-E Outdoor unit RAS-05, 07, 10, 13, 16, 18J2AVG-E 1122950196...
  • Page 2: Table Of Contents

    CONTENTS PRECAUTIONS FOR SAFETY ............................1 ACCESSORY PARTS .................................4 INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS ...................5 Optional Installation Parts ...............................5 INDOOR UNIT ..................................6 Installation Place ................................6 Cutting a Hole and Mounting Installation Plate .......................6 Piping and Drain Hose Installation ..........................6 Indoor Unit Fixing ................................7 Drainage ..................................7 OUTDOOR UNIT .................................8...
  • Page 3: Precautions For Safety

    PRECAUTIONS FOR SAFETY Read the precautions in this manual carefully before This appliance is fi lled with R32. operating the unit. Before installation, please read these precautions for safety carefully. Be sure to follow the precautions provided here to avoid safety risks. The symbols and their meanings are shown below.
  • Page 4 TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE THAN 2 M) FROM HEAT SOURCES SUCH AS RADIATORS, HEATERS, FURNACE, STOVES, ETC. WHEN MOVING THE AIR CONDITIONER FOR INSTALLING IT IN ANOTHER PLACE AGAIN, BE VERY CAREFUL NOT TO GET THE SPECIFIED REFRIGERANT (R32 or R410A) WITH ANY OTHER GASEOUS BODY INTO THE REFRIGERATION CYCLE.
  • Page 5 A special tool for the R32 or R410A refrigerant is required for installation. Thickness of copper pipes used R32 must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm. After completion of installation or service, con fi rm there is no leakage of refrigerant gas.
  • Page 6: Accessory Parts

    ACCESSORY PARTS Indoor Unit Wireless remote control × 1 Installation plate × 1 Battery × 2 Remote control holder × 1 Mounting screw × 6 Flat head wood screw × 2 Owner’s Manual × 1 Installation Manual × 1 Outdoor Unit Cap water proof ×...
  • Page 7: Installation Diagram Of Indoor And Outdoor Units

    (RAS-B05, 07, 10, 13J2KVG-E) 28 mm Air inlet each : Ø12.70 mm 500 mm (RAS-B16J2KVG-E) Air inlet 97 mm (RAS-18J2KVG-E) Pipe insulating material (polyethylene foam, 6 mm thick) Air outlet 90 mm Putty, PVC tapes 600 mm Air outlet each...
  • Page 8: Indoor Unit

    INDOOR UNIT When the installation plate is directly mounted Installation Place on the wall A place which provides the spaces around the indoor unit as shown in the 1. Securely fi t the installation plate onto the wall by screwing it in the upper diagram and lower parts to hook up the indoor unit.
  • Page 9: Indoor Unit Fixing

    How to remove the drain hose NOTE The drain hose can be removed by removing the If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall. screw securing the drain hose and then pulling out After passing the connecting pipe through the pipe hole, connect the the drain hose.
  • Page 10: Outdoor Unit

    2. Put water in the drain pan and make sure that the water is drained out of CAUTION doors. 3. When connecting extension drain hose, insulate the connecting part of Arrange the drain pipe for proper drainage from the unit. extension drain hose with shield pipe.
  • Page 11: Draining The Water

    Refrigerant Piping Connection Draining the Water Flaring the defrost water produced during heating operations is drained off efficiently. 1. Cut the pipe with a pipe cutter. wall, follow the steps below to drain off the water. 1. Proceed with water-proofing by installing the water-proof rubber caps in Obliquity Roughness Warp...
  • Page 12: Evacuating

    Packed valve handling precautions Evacuating Open the valve stem all the way out, but do not try to open it beyond the After the piping has been connected to the indoor unit, you can perform the stopper. air purge together at once. Pipe size of Packed Valve Size of Hexagon wrench AIR PURGE...
  • Page 13: Electrical Works

    ELECTRICAL WORKS Model RAS-B05J2KVG-E RAS-B07J2KVG-E RAS-B10J2KVG-E RAS-B13J2KVG-E RAS-B16J2KVG-E RAS-18J2KVG-E Power source 50Hz, 220 – 240 V Single phase Maximum running current 5.0A 5.4A 7.2A 7.4A 9.0A 9.25A Circuit breaker rating 6.5A 7.0A 9.0A 9.5A 11.5A H07RN-F or Power supply cable H07RN-F or 60245 IEC66 (1.5 mm...
  • Page 14: In Case Of Indoor Unit Connect With 1:1 Outdoor Unit

    In Case of Indoor Unit Connect With 1:1 Outdoor Unit Power Supply Input at Indoor Unit Terminal Block (Recommend) Indoor Unit Outdoor Unit Terminal block Stripping length of the power Power supply cable Power supply cable connect to L N supply cable Terminal block (L N 1 2 3) Earth line...
  • Page 15 Power supply input Wiring Diagram for 1:1 Outdoor Unit Power input at Indoor Terminal Block (Recommend) Indoor Chassis Terminal Block Power input Chassis Outdoor Terminal Block Power input at Outdoor Terminal Block (Optional) Indoor Chassis Terminal Block Chassis Outdoor Terminal Block Power input CAUTION...
  • Page 16: In Case Of Indoor Unit Connect With Inverter Multi System (Ims)

    In Case of Indoor Unit Connect With Inverter Multi System (IMS) Indoor Unit Stripping length of the Connecting cable Connecting cable connect to L 2 3 Connecting cable Terminal block (L N 1 2 3) Earth line 50 mm 10 mm 10 mm 70 mm Earth line...
  • Page 17: Others

    OTHERS Gas Leak Test Test Operation To switch the TEST RUN (COOL) mode, press [RESET] button for 10 seconds. (The beeper will make a short beep.) Check places for the indoor unit. OPERATION / RESET Button Check places for the outdoor unit. Auto Restart Setting Check the fl are nut connections for the gas leak with a gas leak detector This product is designed so that, after a power failure, it can restart automatically...
  • Page 19 1122950196...