Before commissioning the system, check that it is properly installed and connected. The
drive system must be commissioned as described in the operating instructions for the
converter/inverter.
Note
This list below does not claim to be complete. It may be necessary to perform additional
checks and tests in accordance with the specific, on-site situation.
Thermal hazard: hot surfaces
The surface temperature of the motors can exceed 100°C.
Do not touch hot surfaces.
If necessary, implement shock-hazard protection measures.
Temperature-sensitive parts (electric cables, electronic components) must not be placed on
hot surfaces.
Mechanical connection
● All touch protection measures for moving and live parts have been taken.
● The motor has been assembled and aligned properly.
● The rotor can spin unhindered.
● The operating conditions correspond to the data specified on the rating plate.
● All fixing screws, connecting elements, and electrical connections must be tightened and
● The output elements have the proper setting conditions according to type, for example.
Synchronous/induction motors 1PH813
Operating Instructions, 04/2009, 610.48000.22
CAUTION
properly implemented.
– Couplings are aligned and balanced.
– The belt tension is properly adjusted if a belt drive is used.
– Gear tooth flank play and gear tooth tip play as well as radial play are properly
adjusted if a gearwheel drive is used.