7.3

Mechanical environmental conditions

7.3.1

Storage conditions

The following information is for a device that is transported and stored in its original
packaging.
The device was tested according to IEC 60721-3-2:2018 Class 2M4 with the following
amendments and limitations:
Type of condition
Free fall
Vibration according to
IEC 60068-2-6
Shock according to
IEC 60068-2-27
7.3.2

Operating Conditions

The following information applies to a device installed according to the specifications in these
operating instructions.
The devices were tested based on IEC 60721-3-3:2002 Class 3M3 with the following
amendments and limitations:
Built-in devices and Transceiver Unit:
Type of condition
Vibration according to IEC
60068-2-6
Shock according to IEC 60068-2-
27
Applies to built-in devices: Shock pulses within the specified range can be transferred to the
display but do not impact the functionality of the device.
PRO devices
Type of condition
Vibration according to
IEC 60068-2-6
Shock according to IEC 60068-2-
27
Shock pulses within the specified range can be transferred to the display but do not impact
the functionality of the device.
IFP V2, IFP V2 PRO, IFP V2 ETH
Operating Instructions, 03/2023, A5E46641410-AE
7.3 Mechanical environmental conditions
Permitted range
≤ 0.3 m
5 ... 8.4 Hz. deflection 3.5 mm
8.4 ... 500 Hz. acceleration 1 g
250 m/s
, 6 ms, 1000 shocks
2
Permitted range
5 ... 8.4 Hz, deflection 3.5 mm
8.4 ... 200 Hz, acceleration 1 g
150 m/s
, 11 ms, 3 shocks
2
Permitted range
10 ... 58 Hz, deflection 0.0375 mm
58 ... 200 Hz, acceleration 0.5 g
150 m/s
, 11 ms, 3 impacts
2