SUN2000-4.95KTL-JPL0
User Manual
Table 5-1 Cables
No.
Cable
1
DC input
power cable
2
RS485
communicati
ons cable
3
AC output
power cable
4
PE cable

5.3 Connecting a PE Cable

Context
It is recommended that the PE cable of the solar inverter be connected to a
nearby ground point. Connect the PE points of all solar inverters in the same array
to ensure equipotential connections to PE cables. Low-voltage solar inverters need
to be grounded in type C mode.
Procedure
Step 1 Crimp the OT terminal.
● Pay attention not to scratch the core wire when stripping a cable.
● The cavity formed after the conductor crimp strip of the OT terminal is crimped
● Wrap the wire crimping area with a heat shrinkable tube or PVC insulation
● When using a heat gun, protect the solar inverter from being scorched.
Issue 04 (2023-02-17)
Type
Common outdoor PV
cable in the industry
Two-core outdoor
shielded cable
Three-core (U, O, and W)
outdoor copper cable
Single-core outdoor
copper cable
NO TICE
must wrap the core wires completely. The core wires must contact the OT
terminal closely.
tape. The heat shrink tubing is used as an example.
Copyright © Huawei Technologies Co., Ltd.
Conductor
Outer
Cross-Sectional
Diameter
Area Range
4.5–7.8 mm
2
3.5–5.5 mm
4–11 mm
2
0.25–1 mm
10–21 mm
2
3.5–5.5 mm
2
N/A
3.5–5.5 mm
5 Electrical Connections
Source
Prepared by
the
customer
Prepared by
the
customer
Prepared by
the
customer
Prepared by
the
customer