Siemens SIMATIC NET SFP Series Operating Instructions Manual
Siemens SIMATIC NET SFP Series Operating Instructions Manual

Siemens SIMATIC NET SFP Series Operating Instructions Manual

Network components transceiver
Hide thumbs Also See for SIMATIC NET SFP Series:

Advertisement

Quick Links

Transceiver SFP/SFP+/SCP/STP
SIMATIC NET
Network components
Transceiver SFP/SFP+/SCP/STP
Operating Instructions
11/2015
A5E02630804-08
___________________
Introduction
___________________
Safety notes
___________________
Description
___________________
Assembling
___________________
Uninstalling
___________________
Connecting up
___________________
Technical data
___________________
Dimension drawings
___________________
Approvals
1
2
3
4
5
6
7
8
9

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET SFP Series

  • Page 1 ___________________ Transceiver SFP/SFP+/SCP/STP Introduction ___________________ Safety notes ___________________ SIMATIC NET Description ___________________ Assembling Network components Transceiver SFP/SFP+/SCP/STP ___________________ Uninstalling ___________________ Connecting up Operating Instructions ___________________ Technical data ___________________ Dimension drawings ___________________ Approvals 11/2015 A5E02630804-08...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction ............................. 5 Safety notes ............................7 Description .............................. 9 Type designation ........................9 Product overview ........................10 Components of the product ....................12 Assembling ............................13 Notes on installation of SFP / SFP+ transceivers ..............13 Inserting an SFP / SFP+ transceiver ..................
  • Page 4 Table of contents Transceiver SFP/SFP+/SCP/STP Operating Instructions, 11/2015, A5E02630804-08...
  • Page 5: Introduction

    ● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support under the following entry IDs: – 27069465 (http://support.automation.siemens.com/WW/view/en/27069465) Industrial Ethernet / PROFINET Industrial Ethernet System Manual –...
  • Page 6 Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept.
  • Page 7: Safety Notes

    Safety notes Safety notices on the use of the devices The following safety notices must be adhered to when setting up and operating the device and during all associated work such as installation, connecting up, replacing devices or opening the device. General notices regarding use in hazardous areas WARNING Risk of explosion when connecting or disconnecting the device...
  • Page 8 Safety notes WARNING Suitable cables for temperatures in excess of 70 °C If the cable or conduit entry point exceeds 70 °C or the branching point of conductors exceeds 80 °C, special precautions must be taken. If the equipment is operated in an air ambient in excess of 50 °C, only use cables with admitted maximum operating temperature of at least 80 °C.
  • Page 9: Description

    Description Type designation Structure of the type designation The type designation of an pluggable transceiver is made up of several parts that have the following meaning: Interface *) Property 100 Mbps LC port optical, multimode, up to max. 5 km. 1000 Mbps LC port optical, multimode, up to max.
  • Page 10: Product Overview

    Description 3.2 Product overview Product overview Note Fiber monitoring All pluggable transceivers are capable of diagnostics and support fiber monitoring. SFP transceiver Type Properties Article number SFP991-1 * 1 x 100 Mbps, LC port optical for glass FO cable 6GK5 991-1AD00-8AA0 (multimode), up to max.
  • Page 11 Description 3.2 Product overview SFP+ transceiver Type Properties Article number SFP993-1 1 x 10 Gbps, LC port optical for glass FO 6GK5 993-1AT00-8AA0 cable (multimode), up to max. 300 m 1 x 10 Gbps, LC port optical for glass FO 6GK5 993-1AT10-8AA0 cable (multimode), up to max.
  • Page 12: Components Of The Product

    Description 3.3 Components of the product Media modules Note The SFP media modules MM992-2SFP may only be fitted with approved transceivers. The media module can be fitted with up to two pluggable transceivers. The SFP media modules MM992-4SFP may only be fitted with approved transceivers. The media module can be fitted with up to four pluggable transceivers.
  • Page 13: Assembling

    Assembling Notes on installation of SFP / SFP+ transceivers General notes on media modules and pluggable transceivers WARNING Install and remove media modules only when the power is off Media modules may only be inserted in or removed from a SCALANCE device when the power supply to the device has been turned off.
  • Page 14 • The use of transceivers of the types LH, LH+ or ELH. NOTICE Use only approved pluggable transceivers If you use components not approved by Siemens AG, in particular SFP / SFP+ transceivers, Siemens cannot accept any responsibility for the correct functioning of the "Ethernet switch system" according to the specification.
  • Page 15 Note Plugging and pulling during operation With SCALANCE X, the pluggable transceivers can be plugged and pulled during operation. If you have questions on the use of SIMATIC NET products, please contact your Siemens sales partner. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 11/2015, A5E02630804-08...
  • Page 16 Notes on SCALANCE W: Note With a SCALANCE W786-2, do not plug or pull an SFP transceiver during operation! If you have questions on the use of SIMATIC NET products, please contact your Siemens sales partner. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 11/2015, A5E02630804-08...
  • Page 17: Inserting An Sfp / Sfp+ Transceiver

    Assembling 4.2 Inserting an SFP / SFP+ transceiver Inserting an SFP / SFP+ transceiver Figure 4-1 Inserting an SFP / SFP+ transceiver Follow the steps below to insert an SFP / SFP+ transceiver: 1. Remove the sealing plug of the SFP / SFP+ transceiver. 2.
  • Page 18: Notes On Installation Of Scp / Stp Transceivers

    General notes on pluggable transceivers NOTICE Use only approved pluggable transceivers If you use components not approved by Siemens AG, in particular SCP / STP transceivers, Siemens cannot accept any responsibility for the correct functioning of the "Ethernet switch system" according to the specification.
  • Page 19: Inserting An Scp / Stp Transceiver

    Assembling 4.4 Inserting an SCP / STP transceiver Inserting an SCP / STP transceiver Figure 4-2 Inserting an SCP / STP transceiver Follow the steps below to insert an SCP / STP transceiver: 1. Remove the sealing plug of the SCP / STP transceiver. 2.
  • Page 20 Assembling 4.4 Inserting an SCP / STP transceiver Transceiver SFP/SFP+/SCP/STP Operating Instructions, 11/2015, A5E02630804-08...
  • Page 21: Uninstalling

    Uninstalling Removing an SFP / SFP+ transceiver Notes on deinstallation CAUTION Risk of burns due to the high temperatures of the pluggable transceiver The SFP / SFP+ transceivers can be plugged and pulled during operation. Leave the transceiver to cool down as much as possible. Procedure Follow the steps below to remove an SFP / SFP+ transceiver: 1.
  • Page 22 Uninstalling 5.2 Removing an SCP / STP transceiver Procedure Figure 5-1 Removing an SCP / STP transceiver Follow the steps below to remove an SCP / STP transceiver: 1. Remove the connecting cable of the SCP / STP transceiver. 2. Press the spring in the SCP / STP slot to the right using a screwdriver, see figure. The SCP / STP transceiver is pushed part of the way out of the SCP / STP slot.
  • Page 23: Connecting Up

    Connecting up NOTICE Failure of the data traffic due to contamination of optical plug-in connections Optical sockets and plugs are sensitive to contamination of the end face. Contamination can lead to the failure of the optical transmission network. Close unused optical sockets and plugs as well as pluggable transceivers and slots with the supplied protective caps.
  • Page 24 Connecting up 6.2 Power supply Transceiver SFP/SFP+/SCP/STP Operating Instructions, 11/2015, A5E02630804-08...
  • Page 25: Technical Data

    Technical data Mechanical and electrical data Technical specifications Pluggable transceiver Property SFP991-1 1 x 100 Mbps, LC port optical, multimode glass, up to max. 5 km SFP991-1LD 1 x 100 Mbps, LC port optical, single mode glass, up to max. 26 km SFP991-1LH+ 1 x 100 Mbps, LC port optical, single mode glass, up to max.
  • Page 26 Technical data 7.1 Mechanical and electrical data Technical specifications Operating altitude above sea level depending on 2000 m at max. 60 °C • ambient temperature 3000 m at max. 50 °C • *) The ambient temperature depends on the selected device. You will find detailed information on the ambient tempera- tures in the operating instructions of the devices, see section “Introduction (Page 5)“.
  • Page 27 Technical data 7.1 Mechanical and electrical data Electrical data Pluggable transceiver Transmitter output optical Receiver input min. [dBm] max. [dBm] Sensitivity min. max. input power [dBm] [dBm] SFP991-1 SFP991-1LD SFP991-1LH+ SFP991-1ELH200 SFP992-1 -9.5 SFP992-1LD -9.5 SFP992-1LH SFP992-1LH+ SFP992-1ELH SFP+ SFP993-1 SFP993-1LD -8.2 -12.6...
  • Page 28: Cable Lengths

    Technical data 7.2 Cable lengths Cable lengths SFP transceiver Table 7- 1 Permitted cable lengths (fiber-optic) Fast Ethernet Type Fiber FO cable lengths SFP991-1 50/125 µm 0-5 km multimode fiber (1 dB/km at 1310 nm; 1200 MHz*km) 62.5/125 µm 0-5 km multimode fiber (≤1 dB/km at 1310 nm;...
  • Page 29 Technical data 7.2 Cable lengths SFP+ transceiver Table 7- 3 Permitted cable lengths (fiber-optic) gigabit Type Fiber FO cable lengths SFP993-1 50/125 µm 0 - 300 m multimode fiber (3.5 dB/km at 850 nm; 2000 MHz*km: OM3) 0 - 550 m (3.5 dB/km at 850 nm;...
  • Page 30: Other Properties

    Technical data 7.3 Other properties Recommendation for the attenuation of the attenuator on a connection with the same transceivers: Transceiver type Attenuator 6 dB ... 12 dB 12 dB ... 20 dB ELH, ELH200 16 dB ... 24 dB If you have established a connection on a pluggable transceiver with a short cable length, it is possible that the transmitter will be turned off.
  • Page 31: Dimension Drawings

    Dimension drawings SFP dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 11/2015, A5E02630804-08...
  • Page 32: Sfp+ Dimension Drawing

    Dimension drawings 8.2 SFP+ dimension drawing SFP+ dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 11/2015, A5E02630804-08...
  • Page 33: Scp Dimension Drawing

    Dimension drawings 8.3 SCP dimension drawing SCP dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 11/2015, A5E02630804-08...
  • Page 34: Stp Dimension Drawing

    Dimension drawings 8.4 STP dimension drawing STP dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 11/2015, A5E02630804-08...
  • Page 35: Approvals

    EN 61000-6-4 : 2007 EN 61000-6-2 : 2005 EU declaration of conformity You will find EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15273/cert). WARNING Personal injury and property damage can occur...
  • Page 36 You will find information on the system manuals in the section "Introduction (Page 5)", in "Further documentation". – "EMC Installation Guidelines" configuration manual ID = 60612658 (http://support.automation.siemens.com/WW/view/en/60612658) ● Working on the device To protect the device from electrostatic discharge, personnel must first discharge any electrostatic charge from their body before touching the device.
  • Page 37 Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en). Enter the document identification number C234 as the search term. SIMATIC NET products meet the requirements of the EC directive:94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres".
  • Page 38 Approvals The product meets the requirements of the AS/NZS 2064 standard (Class A). KC (Korean Standard) The products meet the requirements of the "Korean Standard". Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) FDA and IEC marks...
  • Page 39 Approvals Mechanical stability (in operation) Pluggable trans- Type IEC 60068-2-6 vibration IEC 60068-2-27 shock ceiver 5 – 9 Hz: 3.5 mm 15 g, 11 ms duration 9 – 150 Hz: 1 g 6 shocks per axis 1 octave/min, 20 sweeps SFP991-1 ●...
  • Page 40 Approvals Transceiver SFP/SFP+/SCP/STP Operating Instructions, 11/2015, A5E02630804-08...
  • Page 41: Index

    Index SFP/SFP+ transceivers Inserting, 17 Notes on installation, 13 SFP+, 21 Article number, 10, 12 SFP+ slot, 21 ATEX, 7 SFP+ transceiver, 11, 21 Attenuation, 29 SIMATIC NET glossary, 6 Attenuator, 29 SIMATIC NET manual, 5 STP transceiver, 11 System manual, 5, 36 Fiber monitoring, 10 Type designation, 9 Glossary, 6...
  • Page 42 Index Transceiver SFP/SFP+/SCP/STP Operating Instructions, 11/2015, A5E02630804-08...

This manual is also suitable for:

Simatic net scp seriesSimatic net stp series

Table of Contents