Interlock Function; External Device Monitor Function - Panasonic WUME-SF4D-2 Instruction Manual

Safety light curtain type 4
Table of Contents

Advertisement

Functions

3-11-3 Interlock Function

Item
Interlock conditions
To use manual reset with optical synchronization, refer to "3-11-10 Cable Switching Function".

3-11-4 External Device Monitor Function

Item
External device moni-
tor function
External device moni-
tor time
120
Description
You can change the conditions
for entering the interlock state.
• Only when the power is turned
ON
• When the device changes
from the light receiving state
to the light blocked state
Description
When the monitoring result
of contact "b" of the external
device is abnormal, the device
enters the lockout state.
When the operation of con-
tact "b" of the external device
exceeds the monitor time, the
device enters the lockout state.
Settings / ranges
Start interlock
• Only when the power is turned
ON
Restart interlock
• When the device changes
from the light receiving state to
the light blocked state
Start / restart interlock
• When the power is turned
ON, and when the device is
blocked
Settings / ranges
Valid
(Enters lockout state)
Invalid
(Does not enter lockout state)
Monitor time:
100 to 600ms (increments of 10ms)
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
Factory default
setting
Start / restart interlock
Factory default
setting
Valid
300ms