4)
Use a Phillips screwdriver to loosen the three fixing screws for the lamp
unit to be replaced until the screws turn freely. Hold the handle of the
lamp unit and gently pull the lamp unit out from the projector.
CAUTION
The lamp unit and structural parts around the
lamp unit will be hot immediately after the
projector has been used.
You might get burned if you touch it while it is still
hot.
5)
Install the new lamp unit.
When inserting the new lamp unit, be
particularly sure to push it in at points
and
.
6)
Use a Phillips screwdriver to securely tighten the lamp unit fixing screws
for each lamp unit.
7)
Install and close the lamp unit cover, and then use a Phillips screwdriver
to securely tighten the lamp unit cover screw.
Firmly install the lamp unit and lamp unit cover.
8)
Replace the static electric mesh filter with the new filter provided as an
accessory with the projector according to the replacement procedure
given in the projector's Operating Instructions ("Cleaning and
replacement of air filter").
Clean the air filter (filter cleaning unit, movable metal mesh filter and
brush) at the same time.
Accessory
Static electric mesh filter
Web Site : https://panasonic.net/cns/projector/
4 - ENGLISH
Fixing screws
Handle
Lamp unit 2
Lamp unit 1
Lamp unit cover screw
Lamp unit cover
Lamp unit 4
Lamp unit 3
Printed in Japan