Hitachi EUB-5500 Technical Manual page 121

Ultrasound diagnostic scanner
Table of Contents

Advertisement

No.
Signal Name
54
S̲CBE<1..0>*
55
S̲AD<15..0>
56
TCICLK
57
TCISYNC
58
TCIEN
59
TCIERR*
60
TCIDA<7..0>
61
TCIDB<7..0>
62
IIS̲SDATA
63
IIS̲LRCK
64
IIS̲SCLK
65
IIS̲MCLK
66
TCK̲MAP1
67
TCK̲MAP2
68
TDO̲MAP1
69
TDO̲MAP2
70
TMS̲COM
71
TDI̲COM
72
CK4F0US̲P
73
CK4F0US̲N
74
CK4F0CW̲P
75
CK4F0CW̲N
76
S̲CLK̲DBF̲P
77
S̲CLK̲DBF̲N
78
S̲CLK̲BIO̲P
79
S̲CLK̲BIO̲N
80
CK32DBF̲P
81
CK32DBF̲N
82
CK64DBF̲P
Terminal No.
IN/OUT
CNF3‑33,35
OUT
CNF3‑
IN/OUT
37,39,41,43,45,47,
49,51,53,55,57,59,
61,63,65,67
CNF6‑1
OUT
CNF6‑3
OUT
CNF6‑5
OUT
CNF6‑7
OUT
CNF6‑
OUT
9,11,13,15,
17,19,21,23
CNF6‑
OUT
25,27,29,31,
33,35,37,39
CNF6‑43
IN
CNF6‑45
IN
CNF6‑47
IN
CNF6‑49
IN
CNF6‑10
OUT
CNF6‑14
OUT
CNF6‑18
IN
CNF6‑22
IN
CNF6‑26
OUT
CNF6‑30
OUT
CNF4‑1
OUT
CNF4‑3
OUT
CNF4‑7
OUT
CNF4‑5
OUT
CNF4‑9
OUT
CNF4‑11
OUT
CNF4‑25
OUT
CNF4‑27
OUT
CNF4‑15
OUT
CNF4‑13
OUT
CNF4‑17
OUT
From/To
DBF‑132B,132C,
BIO‑31A,33A
DBF‑
132A,133A,134A,
135A,133B,134B,
135B,133C,134C,
135C,133D,134D,
135D,133E,134E,
135E
BIO‑
23C,24C,25C,26C,
27C,28C,29C,30C,
31C,32C,33C,34C,
35C,36C,37C,38C
MAP1,2‑CNF6‑1
MAP1,2‑CNF6‑3
MAP1,2‑CNF6‑5
MAP1,2‑CNF6‑7
MAP1,2‑CNF6‑
9,11,13,15,
17,19,21,23
MAP1,2‑CNF6‑
25,27,29,31,
33,35,37,39
MAP1,2‑CNF6‑43
MAP1,2‑CNF6‑45
MAP1,2‑CNF6‑47
MAP1,2‑CNF6‑49
MAP1,2‑CNF6‑10
MAP1,2‑CNF6‑14
MAP1,2‑CNF6‑18
MAP1,2‑CNF6‑22
MAP1,2‑CNF6‑26
MAP1,2‑CNF6‑30
DBF‑126E
DBF‑127E
CW‑105A
CW‑104A
DBF‑146B
DBF‑146A
BIO‑15E
BIO‑16E
DBF‑124E
DBF‑125E
DBF‑125D
8 - 12
Description
S‑PCI Local Bus Control Signal
S‑PCI Local Bus Data Signal
TCI Bus 40ns(25MHz) Clock
TCI Bus Sync Signal
TCI Bus Enable Signal
TCI Bus Error Signal
TCI Bus Data Signal (I‑Data)
TCI Bus Data Signal (Q‑Data)
IIS Audio Serial Data Signal
IIS Audio LR Indicate Signal
IIS Audio Sampling Clock
IIS Audio Master Clock
MAP1 JTAG TCK Signal
MAP2 JTAG TCK Signal
MAP1 JTAG TDO Signal
MAP2 JTAG TDO Signal
MAP1,2 JTAG TMS Signal
MAP1,2 JTAG TDI Signal
Transmission  4  times  Reference
Clock for DBF (Positive Pole)
Transmission  4  times  Reference
Clock for DBF (Negative Pole)
Transmission  4  times  Reference
Clock for CW (Positive Pole)
Transmission  4  times  Reference
Clock for CW (Negative Pole)
S‑PCI Clock for DBF
(Positive Pole)
S‑PCI Clock for DBF
(Negative Pole)
S‑PCI Clock for BIO
(Positive Pole)
S‑PCI Clock for BIO
(Negative Pole)
DBF 31.2MHz (32nS) Clock (Positive
Pole)
DBF 31.2MHz (32nS) Clock (Negative
Pole)
DBF 15.6MHz (64nS) Clock.
(Positive Pole)
L1E-EA0229