12. If a leak is detected, shut gas and electricity off and repair leak.
13. Repeat steps 12 and 13 until no leaks are detected.
14. Replace access panel.
Ignitor
Rollout
Switches
Sensor
Repair Parts List
The
following
repair
independent GEA dealers. When ordering parts, include
the complete furnace model number listed on the CSA
International nameplate. All service must be performed
by a licensed professional HVAC installer (or equivalent),
service agency, or gas supplier.
Cabinet Parts
•
Main access panel
•
Blower panel
•
Top cap
Control Panel Parts
•
Transformer
•
Integrated control
•
Door interlock switch
•
Circuit breaker
Blower Parts
•
Blower wheel
•
Blower housing
•
Motor
•
Motor mounting frame
•
Motor capacitor
•
Blower housing cutoff plate
Page 36 of 38
Manifold And Gas Valve
Figure 27. Burner Removal
parts
are
available
Heating Parts
through
•
Flame sensor
•
Heat exchanger assembly
•
Gas manifold
•
Combustion air inducer
•
Gas valve
•
Main burner cluster
•
Main burner orifices
•
Pressure switch
•
Ignitor
•
Primary limit control
•
Flame rollout switch (s)
•
Secondary limit
Issue 2220
Retention Rings
Cross Over
508145-01G / 31-5000660