1.76 x I
base
I
n
I
base
Figure 4-15
Current duty cycle with prior loading
Derating as a function of the ambient temperature
Permissible output power
100
[%]
Figure 4-16
Derating as a function of the ambient temperature
Booksize Power Sections
Equipment Manual, (GH2), 04.2004 Edition, 6SL3097-2AC00-0BP0
30 s
Base load current (with overload capacity)
300 s
0
20
Ambient temperature
4.2 Motor modules booksize internal air cooling
t
[°C]
40
55
Motor Modules Booksize