Rating - Panasonic PS-A Quick Start Manual

Pressure sensor
Table of Contents

Advertisement

Rating

Standard type
Item
Type of pressure
Pressure medium
Rated pressure (kPa)
Max. applied pressure
Ambient temperature
Storage temperature
Drive voltage
Temperature compensation range
Offset voltage
Rated output voltage
Overall accuracy
Current consumption
Output impedance
Source current
Sink current
Notes : ✽ 1 Please consult us for pressure media other than air.
✽ 2 Indicates output when temperature is 25 °C
✽ 3 Indicates output when drive voltage is 5 V. Although output fl uctuates due to fl uctuations in the drive voltage, this is not included.
✽ 4 Overall accuracy indicates the accuracy of the offset voltage and rated output voltage at a temperature compensation range of 0 to 50 °C
✽ 5 Accuracy is the value at the time of our shipping. Please set Zero-point calibration function on your products in order to safely use if the offset voltage is shifted.
Economy type
Item
Type of pressure
Pressure medium
Rated pressure (kPa)
Max. applied pressure
Ambient temperature
Storage temperature
Drive voltage
Temperature compensation range
Offset voltage
Span voltage
Offset voltage temperature
characteristics
Sensitivity temperature
characteristics
Current consumption
Output impedance
Source current
Sink current
Notes : ✽ 1 Please consult us for pressure media other than air.
✽ 2 Indicates output when temperature is 25 °C
✽ 3 Indicates output when drive voltage is 3 V. Although output fl uctuates due to fl uctuations in the drive voltage, this is not included.
✽ 4 Indicates from output value at 25 °C
✽ 5 Accuracy is the value at the time of our shipping. Please set Zero-point calibration function on your products in order to safely use if the offset voltage is shifted.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Standard type (with glass base)
±100
−100
25
Twice of the rated pressure
−10 °C to +60 °C
−20 °C to +85 °C
2.5±0.05
4.5±0.05
(+when
+100kPa)
77
°F.
Economy type (without glass base)
−5 °C to +50 °C
−20 °C to +70 °C
77
°F.
77 °F
and the change of output at 5 and 45 °C
Pressure Sensor/PS-A (ADP5)
Gauge pressure
Air
50
100
14 °F to +140 °F
(no freezing or condensation)
−4 °F to +185 °F
(no freezing or condensation)
5±0.25 V
0 °C to 50 °C
32 °F to 122 °F
0.5±0.05 V
4.5±0.05 V
±1.25 %FS
Max. 10 mA
15 Ω (Typical)
Max. 0.2 mA
Max. 2 mA
Gauge pressure
Air
40
Twice of the rated pressure
23 °F to +122 °F
(no freezing or condensation)
−4 °F to +158 °F
(no freezing or condensation)
3±0.15 V
5 °C to 45 °C
41 °F to 113 °F
0.3±0.09 V
2.4±0.03 V
±4.0 %FS
1.3 %FS
Max. 3 mA
20 Ω (Typical)
Max. 0.15 mA
Max. 1.5 mA
41 to 113
°F.
200
500
1,000
1.5 times
the rated
pressure
01
Remarks
✽ 1
✽ 2, 3, 5
✽ 2, 3, 5
✽ 3, 4, 5
✽ 2, 3
✽ 2
✽ 2, 3
✽ 2, 3
32 to 122
°F.
Remarks
✽ 1
✽ 2, 3, 5
✽ 2, 3, 5
✽ 3, 4, 5
✽ 3, 4, 5
✽ 2
✽ 2, 3
✽ 2, 3
✽ 2, 3
Feb. 2019

Advertisement

Table of Contents
loading

Table of Contents