Panasonic FP7 Series User Manual page 39

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

1.4 Selection of Power Supply and Restrictions on Combination
Allowable current (24 V) of CPU unit when power is directly supplied
Product name
CPS4R*/CPS3R*
CPU Unit
CPS2R
Expansion Slave Unit
(Note 1)
If the unit is used in an ambient temperature of over 50°C, the consumption current of the unit should
be within the following range.
Output current of power supply units (24V)
Power Supply Unit
● When a power supply unit is used, do not connect a DC power supply to the CPU unit. It is the
same for an expansion slave unit.
● A power supply unit and expansion slave units cannot be connected to the CPU unit CPS2R.
WUME-FP7CPUH-09
AFP7CPS4RE/AFP7CPS3RE/AFP7CPS3R
AFP7CPS4RES/AFP7CPS3RES/AFP7CPS3RS
AFP7CPS2R
AFP7EXPS
Product name
100 to 240V AC, 24W
100 to 240V AC, 3W
Product no.
Product no.
AFP7PSA1
AFP7PSA2
Allowable
maximum current
(Note 1)
3A
(Note 1)
3A
(Note 1)
3A
Rated output current
1A
1.8A
1-13