2
Connect the New Wall Plate
WARNING: Use caution when securing and routing
wires to prevent possible shortage to adjacent terminals.
Insert all wires vertically from the open socket into the
proper terminal. Ensure that each wire is inserted into the
matching terminal. Use the supplied flathead screwdriver
to fasten each wire. Pull wires gently to ensure wires are
securely fastened.
KEY
Rc
Power Cooling
R/h
Power Heating
C
Common
G
Fan
Y
1st Stage Cooling
Y2
2nd Stage Cooling
1st Stage Heating
W/E
Emergency heat activated at W1
2nd Stage Heating
W2
Auxiliary heat activated at W2
O/B
Reverse Valve
H/Dh
(De) Humidifier