Toshiba G3 Workbook page 77

Applications workbook
Table of Contents

Advertisement

G3 Status and Command Bit Tables:
G3 status bit table:
Bit:
0
1
When Off:
Stop
Stop
When On:
Run
Run
Bit:
8
9
When Off:
Feedback
No DC B.
When On:
No Fdbck
DC Break
G3 command bit table:
Bit:
0
1
When Off:
Stop
Not Used
When On:
Run
Not Used
Bit:
8
9
When Off:
Feedback
No DC B.
When On:
No Fdbck
DC Brake
Super User Mode: Using the G3's super user mode, one of the four monitored parameters from the
previous page can be replaced with any one other parameter in the G3. And any one additional G3
parameter can be sent by the PLC to the G3.
Monitoring a different parameter in the G3 using super user mode:
This is an example of setting up the G3 to output the present fault.
1)
Go to super user mode. Only those who have been trained in the use of super user mode should do
this. Severe damage to the drive and motor can result from improper use of super user mode. The
keystrokes used to enter super user mode are not described here.
2)
Go to EEP.
3)
Add H10 to address 36C. For example, if address 36C=HE1, it will become HF1.
4)
Looking at page 59 in the September 1996 RS485 Communications Manual, it can be seen that the
Present Trip is at address H0591.
5)
Set address 370 to 91. This is the low byte of H0591.
6)
Set address 371 to 05. This is the high byte of H0591.
7)
Remove one of the parameters currently being monitored, because only 4 parameters can be
monitored. Do this by changing F10 Monitor Output from 15. Changing to 7 eliminates output
voltage, 11 eliminates output current, 13 eliminates output status bit table, 14 eliminates output
frequency.
8)
In the PLC, AND this received word with H00FF, and pages 62 and 63 of the RS485 manual show
the numerical assignment of these trips. The value will appear immediately after the other
parameters monitored by the PLC. In this example, it will be in LW11.
For additional assistance, please contact Toshiba Adjustable Speed Drive Marketing Dept. at (800) 872-
2
3
4
Reverse
Acc/Dec1
Not Used
Forward
Acc/Dec2
Not Used
A
B
C
VF1
Run
Run
VF2
CoastStop
E-Stop
2
3
4
Reverse
Acc/Dec1
Not Used
Forward
Acc/Dec2
Not Used
A
B
C
VF1
Run
Run
VF2
CoastStop
E-Stop
2192
5
6
7
Bad Gate
Not Used
Normal
Gate OK
Not Used
Jog
D
E
F
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
5
6
7
Not Used
Not Used
Normal
Not Used
Not Used
Jog
D
E
F
Normal
Not Used
Not Used
Reset Trgr Not Used
Not Used
77