SES LCM1061 Occ PIR WH
PIR sensing range
Ceiling installation
Installation height: 2.5-4m (typical value: 3m)
Sensing distance (Figure 1-1): radius 3M (according to NEMA test specification)
This radius is hanging at 3m height,if you hanging at other heights, the inspection
distance will be reduced.
All sensor related specifications are typical and at 25 °C Ta.
�-�
Power
Sensor working voltage range 110-277VAC 50/60Hz
When the load is not connected, the static power consumption is less than 1.2W
Maximum load current 4A (resistive load)
Environment
Storage temperature -25--85℃
Working temperature -20--55℃
The sensor parameters in this paper are based on ta25 ℃.
Product description
No.
12NC
EAN1
EAN3
SAP Description
SES LCM1061 Occ
No.9 911401542802 8719514947610 8719514947627
Surface installation method
Connect the neutral wire N/ live wire L/ output wire OUT through the connector.
The length of tin stripping is 8-10mm, and the installation wire cannot be removed
easily.
8-10mm
2
0.75-1.5mm
Remove installing back cover.
Remove the snap fasteners on both sides.
Route the external power cable into the rear cover of the wall, and fix the rear cover
to the required position using screws.
(2X 4mm)
6mm
Then connect the external power line to the terminal post, and install the housing
into the back cover. (Note: The extra external power cord should be withdrawn from
the sensor, not left inside the sensor)
The concealed installation fixed position shall be able to bear the weight of ≥450g,
(Surface installation should be able to bear the weight of ≥600g).
SIZE
Product protection grade: IP20 (For indoor use only).
Φ94x37.5mm
PIR WH
Embedded installation method
Connect the neutral line N/ live line L/ output line OUT through the connector. The
length of tin stripping is 8-10mm, and the installation line cannot be pulled OUT
easily.
0.75-1.5mm
94 mm
Installing back cover
Installing back cover
≥30mm
External power cable
Torque 0.5-1.2 N·m
Installing back cover
Housing
OFF
ON
8-10mm
2
Opening diameter: φ85-87mm.
85-87mm
Then turn the fixed spring buckle upward and put it into the opening position.
>50mm
≤18mm
Finally, mount the housing together on the wall.
Max.162mm
The concealed installation fixed position shall be able to bear the weight of ≥450g,
(Surface installation should be able to bear the weight of ≥600g).
Product protection grade: IP20 (For indoor use only).
Wiring diagram
L
N
General wiring diagram �
L
N
General wiring diagram �
Max 4A resistive load
......

Advertisement

loading

Summary of Contents for Philips SES LCM1061 Occ PIR WH

  • Page 1 Remove installing back cover. Opening diameter: φ85-87mm. 94 mm SES LCM1061 Occ PIR WH Installing back cover Remove the snap fasteners on both sides. 85-87mm Then turn the fixed spring buckle upward and put it into the opening position. ①...
  • Page 2 Load Peak Inrush Current: < 80A. Technical parameters 2. The sensor installation should be more than 2 meters away from the location of voltage: 100V-277Vac 50/60Hz the air outlet, which includes the air outlet of ventilation pipe, air conditioning air Calculation method of the number of loadable lamps: Divide the inrush current of load: Max 4A resistive load outlet, fan and other air outlet equipment.