Page 4
FCC ID: 2ANWFDW0330 IC: 23237-DW0330 4.5V DC 4.5V DC The DW0330S tool emits a visible laser beam, as shown in Figure . The laser beam emitted is Laser Class 2 per IEC 60825-1 and complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No.
Page 5
Battery Safety By default, distances are measured from the bottom of the tool to a wall or object (Figure WARNING: Batteries can explode or leak and To measure distances from the top or middle of the cause serious injury or fire. To reduce the risk: tool, or from the tool's endpiece (when it is flipped ALWAYS follow all instructions and warnings on open to measure from a corner), click...
Page 6
Measuring Volume Measuring Area You can measure the volume of a room or object. You can measure the area of a wall, floor, or object. Click (Figure ) to turn on the tool. Point the tool's laser (Figure ) toward a wall or object, and not toward anyone's eyes.
Page 7
• If the tool can be positioned opposite the bottom On the bottom line of the display window, view the of the tall object (to create an angle ≤ 45°), use height of the building or object. the distances to 2 points to calculate the height (Figure Adding Measurements •...
Page 8
Click to measure the distance and subtract it Use the DW0330S to measure each wall in the room from the previous measurement. or space captured in the floor plan, and sync the measurements to the floor plan. View the difference between the two measurements...
Page 9
Three Year Limited Warranty WALT will repair, without charge, any defects due to faulty materials or workmanship for three years from the date of purchase. This warranty does not cover part failure due to normal wear or tool abuse. For further detail of warranty coverage and warranty repair information, visit www.D WALT.com or call 1–800–4-D WALT (1–800–433–9258).
Page 10
Specifications Range 6in to 330ft (.15m to 100m) Measuring Accuracy* ± 1/16in (± 1.5mm)* Resolution** 1/16in (1mm)** Laser Class Class 2 (IEC/EN60825-1: 2007/2014) Laser Type ≤ 1.0mW @ 620-690nm Laser/Backlight Automatic Switch-off After 30s Unit Automatic Switch-off After 90s Continuous Measuring Area Volume Pythagoras 2-Point...
Page 11
Caution—use of controls or adjustments or performance —Reorient or relocate the receiving antenna. of procedures other than those specified herein may —Increase the separation between the equipment and result in hazardous radiation exposure. receiver. —Connect the equipment into an outlet on a circuit Caution: different from that to which the receiver is connected.