Reference; Connector Pin Assignment Table; Ccu] Connector; Lan] Connector - Panasonic AK-HRP1005GJ Operating Instructions Manual

Remote operation panel
Table of Contents

Advertisement

Reference

Connector pin assignment table

1 [CCU] connector

(Hirose Electric: HR10A-10R-10P (71))
Pin No.
1
CAM DATA (H)
2
CAM DATA (L)
3
CAM CONT (H)
4
CAM CONT (L)
5
CAM No.A
6
CAM No.B
7
CAM No.C
8
CAM No.D
9
12 V
10
GND

2 [LAN] connector

Complies with 100base-TX.
Allowing connection to a network device that supports the PoE standard (IEEE802.3af compliant).

3 [PREVIEW] connector

(Hirose Electric: HR10A-7R-4PC(73))
Pins 1 and 2 are connectors for outputting the preview signal. Contact output is provided while the IRIS lever is pressed. This is a dry con-
tact.
Pin No.
1
P.VIEW1
2
P.VIEW2
3
EXTRA1
4
EXTRA2
2
Function
Function
ROP→external control
ROP→external control
TALLY→ROP
TALLY→ROP
1
3
Polarity
+
-
+
-
Flow of signal
- 131 -
Reference
Flow of signal
CAM→ROP
CAM→ROP
ROP→CAM
ROP→CAM
Remarks
Dry contact
Dry contact
Dry contact
Dry contact