11.ADDRESS & DATA (1st byte=05H,53H)
Item
SHUTTER
MODE
LEVEL
PEAK/AVE
SPEED
AREA
MANUAL
SYNCHRO
SCAN
Address
Data
H
L
01H
**H
00H
AUTO
01H
MANU
02H
SS
03H
**H
9CH
-100
↓
00H
00
↓
64H
100
04H
**H
00H
00:10
↓
0AH
10:00
05H
**H
00H
1
↓
↓
13H
20
06H
**H
00H
PRESET A
01H
PRESET B
02H
PRESET C
03H
PRESET D
04H
PRESET E
0DH
**H
00H
OFF
01H
1/100S
02H
1/125S
03H
1/250S
04H
1/500S
05H
1/1000S
06H
1/3000S
07H
1/5000S
08H
1/10000S
09H
1/30000S
0AH
1/50000S
0EH
0001H
001/1125H
↓
↓
0230H
560/1125H
Sets the SHUTTER MODE and EXT TRIG mode.
AUTO:Auto shutter
MANU:Manual mode
SS:Synchronous scan mode
Adjusts the automatic shutter level.
↓
Level Low
↑
If the high level is selected, the value increases.
↓
↓
If the low level is selected, the value decreases.
Level High
Adjusts the ratio between peak and average value in the automatic shutter mode.
↓
00:Average only (01 to 09) : The bigger the value is, the higher the ratio is.
10:Peak only
Adjusts the automatic shutter response speed.
The bigger the value is, the faster the response is.
Selects the available picture area in the automatic shutter mode..
PRESET A,B,C,D,E: Specified range
USER:User setting range (Setting area is available)
Sets a shutter speed in manual mode.
Sets a shutter time every time a synchronization scan is turned off or every hour of
data setting.
001H/1125H∼560/1125H:The shutter speed can be set by the 1H.
(1H)
*: don t care
Action
(560H)