Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMP
P
OR
R TA
TANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
TH
H E
P
P
RO
O DUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PE
E
RS
S ON
N AL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Warning:
instructions
Hot surface
Warning:
Switch off
Under pressure
before servicing
or maintenance
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets
and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of
appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. You
must also read and understand the following instructions concerning electrical safety.
Ensure that cables are always protected against short circuit and overload.
Regularly inspect power supply cables and plugs for wear or damage and check all connections
to ensure that none are loose.
Ensure that the voltage marked on the appliance matches the power supply to be
used and that the plug is fi tted with the correct fuse - see fuse rating at right.
DO NOT use worn or damaged cables, plugs or connectors. Have any faulty item repaired or
replaced immediately by a competent electrician.
It is recommended that this device is wired directly to a fused isolator switch. If, however, a plug
is fi tted, the following applies:
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected,
that the cable restraint is tight.
1.1.1.
Model No's SAC3153B and SAC3203B are supplied with a flying lead without a plug. Jack Sealey Limited recommend a 16 amp
protected supply. When connecting to a 16 amp protected supply, contact a qualified electrician to ensure connection to a
suitably rated supply. Provided a good 230V supply is available and the lead length is not increased from that supplied, the
compressor may operate from a 13 amp supply. This very much depends upon the quality of your power supply.
1.1.2.
Wiring a BS 1363/A UK 3 Pin Plug.
WARNING! If in doubt contact a qualified electrician.
A) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
B) Connect the BROWN live wire to the live terminal 'L'.
C) Connect the BLUE neutral wire to the neutral terminal 'N'.
D) Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualifi ed electrician.
1.2.
GENERAL SAFETY
Familiarise yourself with the application and limitations of the compressor.
Ensure the compressor is in good order and condition before use. If in any doubt DO NOT use the unit and contact an electrician/
service agent.
WARNING! Compressor must only be serviced by an authorised agent.
DO NOT tamper with, or attempt to adjust, pressure switch or safety valve.
Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has
been vented.
© Jack Sealey Limited
150L, 200L BELT DRIVE AIR COMPRESSOR
3HP WITH FRONT CONTROL PANEL
MODEL NO:
Wear ear
Electrical shock
protection
hazard
Belt guard
Warning:
must be in
Automatic
place
startup
Original Language Version
SAC3153B, SAC3203B
Wear protective
Wear eye
clothing
protection
Warning
SAC3153B, SAC3203B Issue 4 (3,4,5) 31/03/22
DO NOT
DO NOT
Connect face
open the air
mask directly
cock before
to compressor
an air hose is
attached
Recommended fuse rating
13 Amp