Alarm Groups; Remote Arming Stations (Ras); Data Gathering Panels (Dgp) - GE Alliance AL-2017 Installation Manual

Table of Contents

Advertisement

Alarm groups

1.
Press MENU, enter 1278, and press ENTER to access the system programming.
2.
Enter 19 and press ENTER to access installer programming. Press MENU (advanced menu).
3.
Enter 5 and press ENTER to access alarm group programmaning.
4.
Enter the alarm group number to be programmed and press ENTER.
Note: Care should be taken when programming this function because it can be linked to users, doors, and remote arming
stations. A review of alarm groups in the Alliance System Programming Manual is advised before programming this feature.

Remote arming stations (RAS)

Program RAS to establish communication (polling) with the main control panel. Before a RAS can be programmed, it must be installed
and the DIP switch address on the RAS must be set as shown in the RAS installation instructions.
1.
Press MENU, enter 1278, and press ENTER to access system programming.
2.
Enter 19 and press ENTER to access installer programming. Press MENU (advanced menu).
3.
Enter 3 and press ENTER to access RAS database programming.
4.
Enter the address number of the first RAS to be polled and press ENTER. Repeat for all RAS to be polled and press ENTER again
after all RAS have been polled.
5.
Enter the address number of the first RAS to be configured and press ENTER.
6.
Enter the alarm group number for the RAS and press ENTER.
7.
Enter the menu alarm group number for the RAS and press ENTER.
8.
Enter the door event flag for the RAS, if required, and press ENTER.
9.
Enter the output controller assignment for the RAS and press ENTER.
10. Select Yes, if polling an LCD keypad, and press ENTER.
11. Select Yes, if toggles area status is required, and press ENTER.
12. Select Yes, if enter key opens door only is required, and press ENTER.
13. Select Yes, if door event flag on alarm code is required, and press ENTER.
14. Select Yes, if display shunted zone on LCD is required, and press ENTER.
15. Select Yes, if arm/disarm using one key is required, and press ENTER.
16. Select Yes, if card auto disarm is required, and press ENTER.
17. Select Yes, if card always arms/disarms is required, and press ENTER.
18. Select Yes, if reset from RAS without code is required, and press ENTER.
19. Select Yes, if alarm group restrictions to disarm only is required, and press ENTER.
20. Select Yes, if entry/exit buzzers is required, and press ENTER.
21. Select Yes, if time lockout is required, and press ENTER.
22. Select Yes, if cards arm after 3 badges is required, and press ENTER.
Repeat steps 4 through 21 for each RAS to be configured.

Data gathering panels (DGP)

Program DGPs
to establish communication (polling) with the main control panel. Before a DGP can be programmed, the DGP must be
installed and the DIP switch address on the DGP must be set as shown in the DGP installation instructions.
1.
Press MENU, enter 1278, and press Enter to access system programming.
2.
Enter 19 and press ENTER to access installer programming. Press MENU (advanced menu).
3.
Enter 4 and press ENTER to access DGP programming.
4.
Enter the address number of the first DGP to be polled and press ENTER. Repeat for all DGP to be polled and press ENTER again
when all DGP have been polled.
5.
Enter the address number of the first DGP to be configured and press ENTER.
6.
Enter 0 for standard DGP, 1 for a 4-door controller DGP, or 2 for a 4-elevator controller DGP and press ENTER.
Repeat steps 4 and 5 for all DGP to be configured.
AL-2017/AL-3017 Installation Manual
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alliance al-3017

Table of Contents