Bosch AMAX panel 2100 Quick Installation Manual page 13

Hide thumbs Also See for AMAX panel 2100:
Table of Contents

Advertisement

AMAX panel
Menu Items
1 COM+REPORT MANAG
RECEIVER SETTING
INPUT RECEIVER No.
FORMAT
Figure 5.1: Communications and Reporting Manager
Bosch Sicherheitssysteme GmbH
All manuals and user guides at all-guides.com
Parameters / Description
1-Cid
TEL.No.(17 DIGIT)
Telephone No. </= 17 Digits IP = 12 Dig. + Port = 5 Dig.
SUBSCRIBER ID No.
0 - 9 B - E
2-sia dc03
TEL.No.(17 DIGIT)
Telephone No. </= 17 Digits IP = 12 Dig. + Port = 5 Dig.
SUBSCRIBER ID No.
0 - 9 B - E
3-conettix ip
IP/PORT 17 DIGIT
SUBSCRIBER ID No.
0 - 9 B - E
NETWORK ANTIREPLAY
0-disable 1-enable
NETW. POLLING: min
ACK WAIT TIME: sec
05 - 99 seconds
4-sia dc09
1-Cid
PROTOCOL TYPE
2-sia dc03
IP/PORT 17 DIGIT
DC09 ID No.1(3-16)
LPREF(6 DIGIT)
DC09 RRCVR ENABLE
0-disable 1-enable
RRCVR(6 DIGIT)
0-tcp
TCP/UDP TRANSMIT
1-udp
0-disable
DC09 ENCRYPT. OPT.
1-128 bits key
2-192 bits key
3-256 bits key
DC09 ENCRYPT. KEY
SET TIME ZONE
0=-12:00, 1=-11:00, 2=-10:00, 3=-9:00, 4=-8:00, 5=-7:00, 6=-
6:00, 7=-5:00, 8=-4:30, 9=-4:00, 10=-3:30, 11=-3:00, 12=-
2:00, 13=-1:00, 14=+0:00, 15=+1:00, 16=+2:00, 17=+3:00,
18=+3:30, 19=+4:00, 20=+4:30, 21=+5:00, 22=+5:30,
23=+5:45, 24=+6:00, 25=+6:30, 26=+7:00, 27=+8:00,
28=+8:30, 29=+9:00, 30=+9:30, 31=+10:00, 32=+11:00,
33=+12:00, 34=+13:00, 35=+14:00
0-disable 1-enable
LOCAL TIME SYNC EN
NETW. POLLING: min
ACK WAIT TIME: sec
05 - 99 seconds
5-sia dc09(2xid)
1-Cid
PROTOCOL TYPE
2-sia dc03
IP/PORT 17 DIGIT
DC09 ID No.1(3-16)
DC09 ID No.2(3-16)
LPREF(6 DIGIT)
DC09 RRCVR ENABLE
0-disable 1-enable
RRCVR(6 DIGIT)
0-tcp
TCP/UDP TRANSMIT
1-udp
0-disable
DC09 ENCRYPT. OPT.
1-128 bits key
2-192 bits key
3-256 bits key
DC09 ENCRYPT. KEY
0=-12:00, 1=-11:00, 2=-10:00, 3=-9:00, 4=-8:00, 5=-7:00, 6=-
SET TIME ZONE
6:00, 7=-5:00, 8=-4:30, 9=-4:00, 10=-3:30, 11=-3:00, 12=-
2:00, 13=-1:00, 14=+0:00, 15=+1:00, 16=+2:00, 17=+3:00,
18=+3:30, 19=+4:00, 20=+4:30, 21=+5:00, 22=+5:30,
23=+5:45, 24=+6:00, 25=+6:30, 26=+7:00, 27=+8:00,
28=+8:30, 29=+9:00, 30=+9:30, 31=+10:00, 32=+11:00,
33=+12:00, 34=+13:00, 35=+14:00
0-disable 1-enable
LOCAL TIME SYNC EN
NETW. POLLING: min
ACK WAIT TIME: sec
05 - 99 seconds
Quick Installation Guide
Programming and operating the AMAX panel | en
2016.05 | 06 | F.01U.309.297
13
Certification
Default
1
000000
000000
000000
EN=1
1
1
05
1
000000
0
000001
0
0
0
15
0
1
5
1
000000
0
000001
0
0
0
15
0
1
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amax panel 3000Amax panel 3000 beAmax panel 4000

Table of Contents