Read Input Registers (0X04) - Beko BEKOMAT 16i CO Translation Of Original Installation And Operation Manual

Table of Contents

Advertisement

Original installation and operation manual

3.4.3.1 Read Input Registers (0x04)

Modbus
Contents
address
1116
Main Timer Hi-Word
1117
Main Timer Lo-Word
1102
Main Counter Hi-Word
1103
Main Counter Lo-Word
1540
Temperature Hi-Word
1541
Temperature Lo-Word
1542
Temperature Hi-Word
1543
Temperature Lo-Word
1544
Voltage Hi-Word
1545
Voltage Lo-Word
1700
Status POWER LED
1701
Status ERROR LED
1702
Status Valve LED
1760
Main Button State
3103
Remaining Time Hi-Word
3104
Remaining Time Lo-Word
3105
Remaining Counts Hi-Word
3106
Remaining Counts Lo-Word
3200
Error Flags
3201
Error1 Flag
3202
Error2 Flag
3203
Error3 Flag
3204
Error4 Flag
3205
Error5 Flag
Description / explanation
Operating hours counter [h]
Counter for switching cycles
CPU temperature [°C]
CPU Temperature [°F]
Supply Voltage [V]
LED off = 0
LED 100 % = 1
LED 50 % = 2
LED off = 0
LED 100 % = 1
LED 50 % = 2
LED off = 0
LED 100 % = 1
LED 50 % = 2
Status TEST button
On = 1
Off = 0
Remaining service time [%]
Remaining switching cycles [%]
All Error Flags
Bit 1 = Error1 Flag
Bit 2 = Error2 Flag
Bit 3 = Error3 Flag
Bit 4 = Error4 Flag
Bit 5 = Error5 Flag
Bit 6 = Error6 Flag
Code Flash faulty
1 = Error active
0 = Error inactive
Configuration faulty
1 = Error active
0 = Error inactive
Device not adjusted
1 = Error active
0 = Error inactive
Hardware faulty
1 = Error active
0 = Error inactive
Alarm
1 = Error active
0 = Error inactive
BEKOMAT
16i CO
®
Data type
u32
u32
float
float
float
u16
u16
u16
u16
float
float
u16
u16
u16
u16
u16
u16
19 | 76