Sharp PN-L803C Service Manual page 88

Touch display / touch pen
Hide thumbs Also See for PN-L803C:
Table of Contents

Advertisement

12-4. SYSTEM LOGS AND TAB
Logs are displayed with list format downside. Each item's
meanings are below.
LOG'S MEANING
Header
The smaller the number, the newer
the log data.
ID
Use [ID] to line up in the order of
operation.
It displays date and time when
Date
operation occurred. The icon is
displayed on left edge to stand out, if
"Kind" is "Abnormal State".
It displays the operation time. (The
Time elapsed from
time after turning on the power of the
Power Supply
monitor.)
It displays the kind of log. Detail
Kind
information is described in "Log
Kind".
If "Kind" is "Operation" or "Abnormal
Input
State", it displays the input source of
main screen. If "Kind" is "Change
Signal", it displays the input source
which signal is changed and displays
which screen (Main or Sub)'s signal
is changed in parenthesis. If "Kind" is
"Power Off Reason", it displays
none.
It displays information depending on
Information
"Kind".
Detail information is described in
"Log Kind".
It displays parameter. Detail
Parameter 1/2
information is not open.
LOG KIND
Header
Abnormal State
Log
Change Power
State Log
Change Signal
Log
PN-L803C/80TC3 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 22
Meaning and remark
Meaning and remark
It displays the log about abnormal
state, for example "Temperature
error". Abnormal kind is
displayed in "Information".
It displays the log of power off. The
reason of power change is
displayed in "Information".
It displays the log changing signal.
The timing of new signal is
displayed in "Information" as
"[Width] x [Height] @ [Refresh
rate]" or "No Signal".
Header
Meaning and remark
Operation with IR
It displays the log of
Remote/Key
operations with IR remote
or button on body.
Operation record is
displayed in "Information".
Operation by
It displays the log of
RS-232C
operation by RS-232C
command. The command
(Operation)
is displayed in
"Information".
Extended Operation
The sent command is
by RS-232C
displayed in "Information".
(Operation)
Operation by
It displays the log of
Browser(Operation)
operation by browser. The
command the occurred by
Extended Operation
by Browser
operation
(RS-223C/LAN command)
(Operation)
is displayed in
"Information"
Other Operation
It displays the log of
operation except above,
(Operation)
for example, power off by
schedule timer. Operation
kind is displayed in
"Information".
Developer Info
It displays the Information
for the developer.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pn-80tc3Pn-zl03

Table of Contents