Installation
 Loosen the lug and pull the plug out.
 Loosen the strain relief screw  and
unlock the casing on both sides .
 Open the casing.
 Remove the stopper.
 Exchange the jumper  with the
connection cable of the switching
system.
 Close the casing.
 Tighten the strain relief screw.
 Reinsert the plug.
52
Connecting the e-box
 Connect the fan power cable and fan
control cable to the e-box and the
fan.
 Connect the control unit cable to the
e-box.
The socket positions are designed in
such a way that they cannot be mixed
up.
 Connect the downdraft extractor to
the mains electricity supply.
 Check that the downdraft extractor
works.
Sealing the gaps
 Seal the gaps between the individual
SmartLine appliances, and between
the flush-fit SmartLine appliances
and the worktop, with a silicone
sealant that is heat-resistant to at
least 160 °C.
Unsuitable sealant can damage
natural stone.
For natural stone worktops and
natural stone tiles, only use silicone
sealant that is specially formulated
for natural stone.
Please follow the manufacturer's
instructions.