6.5 Enabling the Remote Power On Function

Do not directly touch the parts inside the equipment with your hand when you
install or remove a jumper socket. Those parts are hot and if you touch them,
you may get burned. In addition, if you touch them, they may get damaged and
that may result in failure of the equipment.
When you use the remote power on function of the optional RAS external control port,
remove the jumper socket attached to the JP2 pins on the motherboard. Whether a jumper
socket is attached determines whether the function of the external contact GENDI2 is a
general-purpose digital input signal or the remote power on signal. (See "5.8.2 External
control specification".)
(1) Before attaching or removing a jumper socket
・ Before starting to work, see "6.3.2 Before installing or removing components".
CAUTION

Table 6-4 Remote Power On setting

Whether a jumper
socket is attached
Attached
Not attached
6-27
6. CHECKUP AND MAINTENANCE
GENDI2 setting
General-purpose digital
input signal
Remote power on signal