Download Print this page

Panasonic Switch-M24eGLPWR+ Manual page 4

Hide thumbs Also See for Switch-M24eGLPWR+:

Advertisement

Model
Switch-M24eGLPWR+
Name
Model
PN28248-SG
No.
5. Hardware Specifications
5-4. LED display
5-5. Cascade connections
6. Software Specifications
6-1. Configuration
6-2. Switching Hub Control
6-3. Rebooting
6-4. Supported Agent
Date issued
Date revised
Product Specification
(7) Port LED (left)
Green light (when the LOOP HISTORY LED lamp is off)
Green light (when the LOOP HISTORY lamp is flashing)
Green flashing
Orange light
Off
(8) Port LED (right)
Green light
Orange flashing : Overload power supply (ports 1 to 24 only)
Off
Displays the Auto MDI/MDI-X function settings.
Ports 1-24 are set to "Disable," and Ports 25-26 are set to "Enable" at factory default
setting.
Control parameters can be set by the following procedures:
(1) Configuration from an asynchronous terminal connected to the console port.
(2) Configuration from a remote terminal connected via TELNET and SSH
(3) Configuration from a remote terminal via the Internet
Switching Hub can be controlled by the following procedures:
(1) Control from an asynchronous terminal connected to the console port.
(2) Control from a remote terminal using SSH/TELNET and TCP/IP network
connection
(3) Control using SNMP Manager
The switching Hub operation status can be checked using the following functions.
(1) Fan sensor function
(2) Internal temperature sensor function
(3) Function to display the CPU usage and memory usage
(4) SFP module status checking function (DDM: Digital Diagnostic Monitoring)
The system can be reset from the software in the following three modes:
(1) Warm start
(2) Reset to factory default
(3) Reset items other than the IP address to factory default
The reboot timer function can also be used in each mode.
Management protocol
Data transfer protocol
July 4, 2016
: Link is established at 10/100/1000 Mbps.
: Within three days after a loop has been eliminated
: Data is being sent/received at 10/100/1000 Mbps.
: Shut off by the loop detection/shutoff function
: No terminal is connected or the ECO mode is set.
: Power is supplied normally. (Ports 1 to 24 only)
or overload in a single port.
: Power is not supplied or PoE receiving equipment is not
connected.
LED(Left)
:SNMP v1/v2c (RFC1157,RFC1901)
TELNET
SSH v2
:TFTP
Panasonic Eco Solutions Networks Co., Ltd.
401-28248-SG-SP01
Page 4 of 10
LED(Right)
(RFC854)
(RFC4251,RFC4252,
RFC4253,RFC4254,RFC4716)
(RFC783)

Advertisement