Fault Logger; How To View Faults; How To Reset Faults - ABB ACSM1 Control Panel User Manual

Hide thumbs Also See for ACSM1 Control Panel:
Table of Contents

Advertisement

Fault Logger

In the Fault Logger option, you can:
• view the drive fault history
• see the details of the most recent faults
• start, stop, change the direction and switch between local and remote control.

How to view faults

Step
Action
1.
Go to the Main menu by pressing
EXIT
by pressing
2.
Go to the Fault Logger option by selecting FAULT LOGGER on the menu with
keys
and
• If there are no faults in the fault history, corresponding text will be shown.
• If there is a fault history, the display shows the fault log starting with the most
recent fault. The number on the row is the fault code according to which the
causes and corrective actions are listed in appropriate Firmware Manual.
• To see the details of a fault, select it with keys
DETAIL
.
• Scroll the text with keys
• After reading it, press

How to reset faults

Step
Action
1.
When a fault occurs, text identifying the fault is shown.
• To reset the fault, press
• To return to the previous display, press
MENU
if you are in the Output mode, otherwise
repeatedly until you get to the Main menu.
ENTER
, and pressing
.
and
EXIT
to return to the previous display.
RESET
.
EXIT
and
, and press
.
.
Display
LOC
MAIN MENU
PARAMETERS
FAULT LOGGER
TIME & DATE
EXIT
00:00
ENTER
LOC
MESSAGE
No fault history
found
LOC
FAULT LOGGER
36:
LOCAL CTRL LOSS
29.04.08 10:45:58
EXIT
00:00
DETAIL
LOC
LOCAL CTRL LOSS
TIME
10:45:58
FAULT CODE
36
FAULT CODE EXTENSION
EXIT
00:00
Display
LOC
FAULT
FAULT 36
LOCAL CTRL LOSS
RESET
EXIT
Operation