3 System Messages

A.3
System Messages
The table below contains all messages that the SIMEAS R-PMU logs in the log file:
Legend:
Type 0: Malfunction
Type 1: Warning / important message
Type 2: Operating message
Log No. Type
Class
258
1
BOOT
260
0
BOOT
262
1
SYSTEM
263
0
SYSTEM
265
1
SYSTEM
266
1
SYSTEM
267
1
SYSTEM
268
1
SYSTEM
269
0
SYSTEM
270
0
SYSTEM
273
1
SYSTEM
274
0
SYSTEM
277
2
SYSTEM
278
0
SYSTEM
279
2
SYSTEM
280
0
SYSTEM
281
0
SYSTEM
282
1
SYSTEM
283
0
SYSTEM
284
1
SYSTEM
285
1
SYSTEM
286
1
SYSTEM
287
0
SYSTEM
288
0
SYSTEM
289
2
SYSTEM
290
2
SYSTEM
280
Description
Reboot initiated
Fault: Task monitor initiating reboot
Create system data OK
Create system data canceled with fault
Read system data OK
System data missing or wrong, new file
written
Write system data OK
Shutdown measurement system
Restart due to critical system fault
(deadlock). Fault time:
Restart due to critical system fault
(deadlock). Task:
DAU not plugged
DAU boot fault
Self-monitoring
Fault: Cannot start self-monitoring
Self-monitoring: New MD5 checksum file
created
Self-monitoring fault: Cannot write MD5
checksum file
Self-monitoring fault: Critical checksum fault Flash disk fault; Hotline
Firmware update
Firmware update failed
Communication subsystem not started.
Reason:
Measurement system not started. Reason:
Number of device restarts due to critical
system faults:
Fault writing the restart counter
Last restart due to critical system fault
Restart information written
Fault writing the restart information
Comment
-
Hotline
Reorganization of system internal data,
e. g. after upgrade or update
Hotline
-
Reorganization of system internal data,
e. g. after upgrade
-
Possible reasons: Change to service mode,
DAU error or device is being shut down
Hotline
Hotline
Status message
Several possible reasons: DAU and CPU
software version do not match, firmware
update recommended; DAU hardware error;
contact hotline if necessary
-
Hotline
Checksum file is created again after each
firmware update
Hotline
-
Hotline
Hotline
Possibly an error message after an
upgrade, otherwise firmware or OSCOP P
update recommended; contact hotline if
necessary
For further information on this fault, refer to
detailed log entries.
Hotline
Hotline
-
Hotline
Digital Fault Recorder, SIMEAS R-PMU, Manual
E50417-H1076-C360-A5, Release 10.2012

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents