Summary of Contents for Siemens SIMOTICS M-1FE2

  • Page 3 SIMOTICS M-1FE2 built-in motors Introduction Fundamental safety instructions SIMOTICS Description Mechanical properties Drive technology SIMOTICS M-1FE2 built-in motors Motor components and options Configuration Configuration Manual Preparing for use Installation Connecting Technical data and characteristics Dimension drawings Environmental compatibility Appendix A...
  • Page 4 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 5: Introduction

    The following link provides information on how to create your own individual documentation based on Siemens content, and adapt it for your own machine documentation: http://www.siemens.com/mdm Training The following link provides information on SITRAIN - training from Siemens for products, systems and automation engineering solutions: SITRAIN (http://siemens.com/sitrain) SIMOTICS M-1FE2 built-in motors...
  • Page 6 Country-specific telephone numbers for technical support are provided on the Internet under Contact: Technical Support (https://support.industry.siemens.com/cs/ww/en/ps) Internet addresses for drive technology Internet address for motors: http://www.siemens.com/motors Internet address for products: http://www.siemens.com/motioncontrol Internet address for SINAMICS: http://www.siemens.com/sinamics Target group This documentation addresses project planners and project engineers as well as machine manufacturers and commissioning engineers.
  • Page 7 Siemens does not control the information on these websites and is not responsible for the content and information provided there. The user bears the risk for their use.
  • Page 8 Introduction SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 9: Table Of Contents

    Temperature evaluation using the PTC thermistor triplet (full motor protection, option) ..52 4.1.1.3 Temperature evaluation using NTC thermistors (universal protection, option) ..... 52 4.1.1.4 Possible connections ......................54 4.1.2 Encoder ..........................58 4.1.3 Cooling ..........................60 4.1.3.1 Cooling circuit ........................60 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 10 Connection assignment of the encoder ................117 8.2.1.5 Terminal box ........................118 8.2.1.6 Recommended grounding ....................118 8.2.1.7 High-voltage test ......................119 8.2.2 Voltage limitation (applies to synchronous motors only) ........... 119 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 11 Technical data for the asynchronous version ..............145 Characteristics ......................... 146 Dimension drawings .......................... 147 Environmental compatibility ......................149 Appendix A ............................151 Technical data and dimensions of the recommended series reactors ......... 151 Index ..............................157 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 12 Table of contents SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 13: Fundamental Safety Instructions

    Contact with hazardous voltage can result in severe injury or death. • Only use power supplies that provide SELV (Safety Extra Low Voltage) or PELV- (Protective Extra Low Voltage) output voltages for all connections and terminals of the electronics modules. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 14 • Tighten all power connections to the prescribed torque. • Check all power connections at regular intervals, particularly after equipment has been transported. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 15 • Therefore, if you move closer than 20 cm to the components, be sure to switch off radio devices or mobile telephones. • Use the "SIEMENS Industry Online Support app" only on equipment that has already been switched off. WARNING Unrecognized dangers due to missing or illegible warning labels Dangers might not be recognized if warning labels are missing or illegible.
  • Page 16 • When transporting or storing permanent-magnet motors always use the original packing materials with the warning labels attached. • Clearly mark the storage locations with the appropriate warning labels. • IATA regulations must be observed when transported by air. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 17 • Mount the motor so that it is not accessible in operation. Measures when maintenance is required: • Allow the motor to cool down before starting any work. • Use the appropriate personnel protection equipment, e.g. gloves. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 18: Equipment Damage Due To Electric Fields Or Electrostatic Discharge

    – Wearing ESD shoes or ESD grounding straps in ESD areas with conductive flooring • Only place electronic components, modules or devices on conductive surfaces (table with ESD surface, conductive ESD foam, ESD packaging, ESD transport container). SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 19: Security Information

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to...
  • Page 20: Residual Risks Of Power Drive Systems

    6. Influence of network-connected communication systems, e.g. ripple-control transmitters or data communication via the network For more information about the residual risks of the drive system components, see the relevant sections in the technical user documentation. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 21: Description

    If you wish to use special versions and design variants whose specifications vary from the motors described in this document, then contact your local Siemens office. If you have any questions regarding the intended usage, please contact your local Siemens office.
  • Page 22: Overview Of The Motors

    • Commission the machine only when it conforms to the regulations of the EU 2006/42/EU machine decree and the conformity has been declared. Overview of the motors The 1FE2 built-in motors are supplied as components. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 23 Frame sizes 16-pole 1FE218.-8L.. (shaft heights) A complete motor is created after the rotor has been mounted into the stator. As a rule, the built-in motor is installed in a motor spindle. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 24 Figure 2-1 Motor spindle design Note The spindle manufacturer is responsible for designing the bearings, lubrication and cooling. A ferritic spindle shaft is a prerequisite in order to achieve the electrical parameters. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 25: Technical Features And System Requirements

    Installed and operated with a converter, the motor - together with the Power Drive System - must comply with the requirements laid down in the applicable EMC Directive. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 26 UL or cUL mark on the rating plate! Quality systems Siemens AG employs a quality management system that meets the requirements of ISO 9001 and ISO 14001. Certificates for SIMOTICS motors can be downloaded from the Internet at the following link: Certificates for SIMOTICS motors (https://support.industry.siemens.com/cs/ww/de/ps/13347/cert)
  • Page 27: Technical Features

    UL marking The motors are UL-1004 certified. Note Technical specifications are system data and applicable only in conjunction with the specified system components (1FE2 built-in motor, SINAMICS S120 drive system, VPM, etc.). SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 28: Rotor Weights And Moments Of Inertia

    Mass without cooling jacket in kgm in kg in kg 1FE2093-8A☐☐☐-☐☐☐☐ 0.0203 1FE2094-8A☐☐☐-☐☐☐☐ 0.0266 1FE2094-8C☐☐☐-☐☐☐☐ 0.0377 12.2 1FE2095-8C☐☐☐-☐☐☐☐ 0.0443 14.3 1FE2145-8C☐☐☐-☐☐☐☐ 0.2667 36.1 1FE2147-8C☐☐☐-☐☐☐☐ 0.3589 48.6 The mass values are rounded. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 29: System Requirements

    If you operate the motors with older software versions, you must commission the motors as if they were made by other manufacturers. This may involve limitations of the technical performance. Contact your Siemens Technical Support for more information. • Hollow-shaft measuring system Parameterizing the converter The rated data of the motors applies for a converter pulse frequency of 4 kHz.
  • Page 30 DRIVE CLiQ communication via SMC20 1FE2 built-in motor Signal cable for encoder and temperature sen- sor, 17-pin M23 round connector 21 Incremental encoder sin/cos 1 Vpp or EnDat 2.1 absolute encoder SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 31 22 1FE2 winding, connection via terminal box format, DRIVE CLiQ communication via SMC20 12 Tripping unit Signal cable for encoder and temperature sensor, 17-pin M23 round connector 1FE2 built-in motor Signal cable for PTC via tripping unit SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 32 DRIVE CLiQ communication via SMC20 1FE2 built-in motor Signal cable for encoder and temperature sen- sor, 17-pin M23 round connector 21 Incremental encoder sin/cos 1 Vpp or EnDat 2.1 absolute encoder SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 33 22 1FE2 winding, connection via terminal box format, DRIVE CLiQ communication via SMC20 12 Tripping unit Signal cable for encoder and temperature sensor, 17-pin M23 round connector 1FE2 built-in motor Signal cable for PTC via tripping unit SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 34: Design Of The Motor In The Synchronous Version

    Design of the rotor core (APM) APM rotors are rotors with externally located permanent magnets. The rotors of built-in motors are finish machined and mounted directly onto the motor spindle shaft without requiring any subsequent machining. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 35 After the rotor is mounted on the spindle, the rotor-spindle system can be finely balanced with the available balancing levels on the rotor. Two all-round grooves are used for accommodating the balancing weights. (See the figure Design of APM rotors, position ②) SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 36 Stator with cooling jacket (standard version) Stator core in cross-section Cables for power connection and temperature O-ring seal sensors Thread for axial fixation Winding overhang Stator core Leakage channel Cooling jacket with cooling duct Impregnated winding SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 37: Design Of The Motor In The Asynchronous Version

    Design of the stators for the asynchronous version Stator without cooling jacket Cables for power connection and tempera- ture sensors Winding overhang, cast Stator core Figure 2-5 Stator without cooling jacket, cast, cross-section SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 38: Nameplate Data

    Maximum speed via frequency converters in rpm Mass of stator and rotor in kg Maximum amperage in A Maximum torque in Nm Technical specifications for S1 and S6 40% 2 min SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 39: Rating Plate Details (Type Plate) Of 1Fe2 In Asynchronous Version, Star Connection

    °C, pressure of the cooling system in MPa Manufacturer's address Mass of stator and rotor in kg Identification temperature sensor Maximum values of the motor Technical specifications for S1 Type of construction SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 40: Rating Plate Details (Type Plate) Of 1Fe2 In Asynchronous Version, Star-Delta Connection

    Maximum values of the motor for delta connection Technical specifications for S1 operation with delta connection Maximum values of the motor for star connection Technical specifications for S1 operation with star connection Type of construction SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 41: Selection And Ordering Data

    If more than one motor is operated in parallel on one drive system, the total (summed) values of the peak and continuous currents must be taken into account. Use the SIZER (https://support.industry.siemens.com/cs/document/54992004/sizer-for- siemens-drives?dti=0&pnid=13434&lc=en-WW) engineering tool to select the appropriate Motor Module. NOTICE Damage to the insulation on synchronous built-in motors on regulated infeed units Where synchronous built-in motors are used together with regulated (closed-loop controlled) infeed units (e.g.
  • Page 42: Structure Of The Article No

    350 mm (all except 1FE218☐) G1☐ Special length 200 mm (1FE218☐ only) 250 mm (1FE218☐ only) 300 mm (1FE218☐ only) 350 mm (1FE218☐ only) 400 mm (1FE218☐ only) 450 mm (1FE218☐ only) SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 43 (on request) Rotor core with standard sleeve Q1☐ Special version Version With Pt1000 temperature sensor - star connection With Pt1000 temperature sensor - star-delta connection Options Rotor prebalanced (only available for 1FE218☐-8L) SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 44 Description 2.8 Structure of the Article No. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 45: Mechanical Properties

    16-pole 1FE2182-8LN 1FE2182-8LH 1FE2183-8LN 1FE2183-8LH 1FE2184-8LN 1FE2184-8LK 1FE2184-8LH 1FE2185-8LN 1FE2185-8LL 1FE2185-8LH 1FE2186-8LN 1FE2186-8LM 1FE2186-8LH 1FE2187-8LN 1FE2187-8LH 8-pole 1FE2093-8A 1FE2094-8A 1FE2094-8C 1FE2095-8C 1FE2145-8C 1FE2147-8C SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 46 To ensure torque transmission without any play, in the area of the interference fit, the spindle must be machined with the specified dimensions and tolerances. Additional information is provided in the dimension drawing in Chapter "Dimension drawings (Page 147)". SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 47: Degree Of Protection

    When delivered, the stator and the rotor have degree of protection IP00 in accordance with EN 60034-5. The spindle manufacturer defines the final degree of protection as a result of the mechanical design of the spindle housing. Recommended degree of protection: at least IP54 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 48: Permissible Motor Vibration Levels

    Maximum permitted axial vibration values Vibration velocity Vibration acceleration = 4.5 mm/s = 2.25 m/s peak Figure 3-1 Maximum permissible vibration velocity taking into account the vibration displacement and vibration acceleration SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 49 The vibration acceleration must be evaluated in a frequency band of 10 ... 2000 Hz. Note If vibration excitation levels > 2000 Hz (e.g. gear teeth meshing frequencies) can be expected, you must adapt the measurement range accordingly. The permitted maximum values remain unchanged. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 50 Mechanical properties 3.3 Permissible motor vibration levels SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 51: Motor Components And Options

    • Ensure that no temperature-sensitive parts are in contact with hot surfaces. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 52: Thermal Motor Protection With Temperature Sensors (Standard Protection)

    The resistance change is proportional to the change in the winding temperature. The temperature characteristic is taken into account in the closed-loop control. The following diagram shows the resistance characteristic as a function of the temperature for Pt1000 temperature sensors. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 53 Destruction of the motor for a thermal critical load A thermally critical load, e.g. high overload when the motor is stationary, can destroy the motor. • Employ additional protective measures, e.g. an overcurrent relay. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 54: Temperature Evaluation Using The Ptc Thermistor Triplet (Full Motor Protection, Option)

    NTC K227 and NTC PT3-51F thermistors are used if the drive system cannot evaluate Pt1000 thermistors. They are intended for operating the motor on third-party systems. The NTC thermistor should be connected in accordance with the configuration and operating instructions of the third-party system. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 55 Resistance when hot (100 °C) Approx. 1800 Ω Approx. 3300 Ω Connection Via the encoder cable Possible connections (Page 54) cable cross-section 0.14 mm 0.14 mm Outer diameter 0.8 mm 0.8 mm Temperature characteristic SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 56: Possible Connections

    • PTC via thermistor motor protection 3RN2013-1GW30, Pt1000 to SMC20 or SME20 • PTC via thermistor motor protection 3RN2013-1GW30, Pt1000 directly connected to the drive system • PTC and Pt1000 connected to SME120 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 57 SINAMICS Control Unit Manual and supplementary system component documentation. Note SME20 Additional information about connecting-up and operating the SME20 is provided in the SINAMICS Control Unit Manual and supplementary system component documentation. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 58 Connecting the PTC via thermistor motor protection 3RN2013-1GW30, Pt1000 without SMC/SME, directly to the drive system Connecting the PTC via thermistor motor protection 3RN2013-1GW30, Pt1000 Figure 4-3 directly to the drive system SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 59 Connecting the PTC and Pt1000 to SME120 Figure 4-4 Note SME120 Additional information about connecting-up and operating the SME120 is provided in the SINAMICS Control Unit Manual and supplementary system component documentation. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 60: Encoder

    • Comparable hollow shaft encoder system with sinusoidal voltage signals 1 Vpp. Note The encoder system is not included in the scope of supply. Figure 4-5 Encoder mounting schematic Measuring systems from different manufacturers can be used. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 61 The recommended encoder systems are third-party products with fundamental suitability. The user must check and ensure the necessary compatibility of the encoder systems for the associated applications. Siemens cannot guarantee the properties/features of third-party products. Contact the specified manufacturer directly for technical information or questions regarding orders.
  • Page 62: Cooling

    When using different conductive materials, material damage can occur as a result of the electrochemical series. • Do not use any zinc in the cooling circuit. • Use brass, stainless steel or plastic for pipes and fittings. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 63 Pipes, valves and The use of FKM, AFM34, EPDM is recommended. fittings Hose connections Transition Secure with clips conforming to DIN 2817, available e.g. from the Pipe - hose Telle company. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 64: Configuring The Cooling Circuit

    Select the smallest possible pressure difference between the supply and return so that pumps with a flat characteristic curve can be used. • Set the required coolant flow rate per time unit according to the technical data of the equipment and motors. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 65: Pressure Loss

    If various components are connected up in the cooling circuit, it may be necessary to provide pressure equalization. Reactor elements are installed at the coolant outlet of the motor or the relevant components. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 66 Operation up to +40 °C coolant inlet temperature is possible with derating (reduced power). Torque reduction referred to M as a % Coolant inlet temperature in °C Figure 4-6 Influence of the coolant inlet temperature on M as a percentage SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 67: Cooling Powers To Be Dissipated (Power Loss)

    The cooling power to be dissipated depends on the rated power P of the motor. If the motor is operated with reduced power, then the cooling power to be dissipated decreases in an approximately linear relationship. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 68: Calculation Of The Cooling Power To Be Dissipated (Power Loss)

    4200 1000 1FE2185-8LN☐☐-☐CC1 62.0 2420 1FE2185-8LL☐☐-☐CC1 86.6 3440 1FE2185-8LH☐☐-☐CC1 122.5 4200 1000 1FE2186-8LN☐☐-☐CC1 71.8 2400 1FE2186-8LM☐☐-☐CC1 86.2 3000 1FE2186-8LH☐☐-☐CC1 142.4 4200 1000 10.9 1FE2187-8LN☐☐-☐CC1 80.1 2670 1FE2187-8LH☐☐-☐CC1 158.9 4200 1000 12.2 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 69 18.5 1300 0.95 4.05 1FE2094-8CG☐☐-☐☐☐2 1050 1FE2094-8CG☐☐-☐☐☐2 18.5 3200 1FE2095-8CJ☐☐-☐☐☐1 22.5 1250 3.75 1.15 1FE2095-8CG☐☐-☐☐☐2 18.5 1000 1FE2095-8CG☐☐-☐☐☐2 3000 1FE2145-8CE☐☐-☐☐☐1 1FE2145-8CC☐☐-☐☐☐2 1FE2145-8CC☐☐-☐☐☐2 1500 0.35 2.05 1FE2147-8CE☐☐-☐☐☐1 1FE2147-8CC☐☐-☐☐☐2 1FE2147-8CC☐☐-☐☐☐2 1300 2.35 0.45 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 70: Coolant

    • Replenish antifreeze for operation (see Table "Coolant water specifications"). Note • Avoid mixing different antifreeze products. • Use and dose the antifreeze according to the manufacturer’s specifications. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 71: Other Coolant

    η Flow rate l/min Third-party cooling jacket Cooling jacket geometry is required Contact your local Siemens office for the power reduction (derating) resulting from the values. See also Technical Support (https://support.industry.siemens.com/cs/ww/en/ps) SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 72 – Bacteria that cause deposits of iron • Add a biocide that counters the determined microbes to the cooling water. The manufacturer's recommendations must be followed in regard to the dosage and compatibility with any inhibitor used. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 73: Commutation Angle And Pole Position Identification

    This "synchronization angle" relative to the zero mark of the encoder system can be measured and saved in the drive system (commutation angle offset). Precondition You are using the "STARTER" wizard for the commissioning. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 74 If the angle is already known, e.g. from the final acceptance report, use this value to check the determined value. Note Deviations > 5° In the case of deviations > 5°, contact the authorized technical personnel of the manufacturer. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 75: Configuration

    10.The current demand of the 24 V DC supply for the components is calculated and the power supplies (SITOP devices, Control Supply Modules) specified 11.The components for the connection system are selected 12.The components of the drive line-up are configured ☐ SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 76 The motor-specific limiting characteristics provide the basis for defining the motors. The limiting characteristics define the torque characteristic with respect to speed and take into account the motor limits based on the line supply voltage and the function of the infeed. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 77 Use different characteristics for the different loads. The following operating scenarios have been defined: • Load duty cycles with constant on period • Load duty cycles with varying on period • Duty cycle, variable SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 78 The base load torque must lie on or below the S1 characteristic. In the event of transient overloads (e.g. when accelerating) an overload has to be taken into consideration. For synchronous motors, the peak torque must lie below the voltage limiting characteristic. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 79 Continuous operation (S1) for x h (without water cooling) Figure 5-2 Selecting motors for load duty cycles with a constant on period Note Free convection must be possible for operation without water cooling. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 80 Take account of an overload for duty cycles with different ON periods. Note For duty cycles in the field weakening range, the calculation tool SIZER for SIEMENS Drives must be used. The following formulas can be used for duty cycles outside the field weakening range.
  • Page 81 M in Nm; n in rpm AP 1 = 400 Nm at 100 rpm AP 2 = 0 Nm at 0 rpm Figure 5-5 Selecting motors for load duty cycles with varying on periods SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 82 Note For duty cycles in the field weakening range, the calculation tool SIZER for SIEMENS Drives must be used. The following formulas can be used for duty cycles outside the field weakening range.
  • Page 83 As a result, the motor is dimensioned as follows: SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 84 1. Select a motor that precisely fulfills the operating conditions 2. Determine the motor current at base load 3. Check that the thermal limits are maintained 4. Define the other properties of the motor. Configure the motor options ☐ SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 85: Help When Configuring

    (http://siemens.de/dt- konfigurator): 5.2.2 SIDIM configuration tool The SIDIM configuration tool supports you in the calculation of the drive of SIMOTICS M-1FE2 built-in motors. You can find additional information that you can download in the Internet at SIDIM (https://support.industry.siemens.com/cs/ww/de/view/25297647). SIMOTICS M-1FE2 built-in motors...
  • Page 86: Sizer Configuration Tool

    • Installation information of the drive and control components • Energy considerations of the configured drive systems You can find additional information that you can download in the Internet at SIZER (https://support.industry.siemens.com/cs/document/54992004/sizer-for-siemens- drives?dti=0&pnid=13434&lc=en-WW). SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 87: Preparing For Use

    (ISO 7000, No. 0621) (ISO 7000, No. 0626) This way up Do not stack (ISO 7000, No. 0623) (ISO 7000, No. 2402) The following chapter describes the scope of delivery of the built-in motors. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 88 Safety information and instruction leaflet. The URL to download the installation instructions is provided on the instruction leaflet not illustrated SINAMICS converter settings and circuit diagram as adhesive label Figure 6-1 Scope of delivery of the synchronous version of the 1FE2 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 89 Procedure • Check the shipment immediately for completeness and for damage. Note Siemens will not accept any claims relating to items missing from the delivery and which are submitted at a later date. • Register a complaint about – any apparent transport damage with the delivery agent immediately.
  • Page 90: Transportation And Storage

    • Transport the motor carefully. • Avoid any jerky and oscillating movements during transport. If a motor is not installed immediately after the delivery, it must be stored appropriately. Observe the following storage conditions. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 91 ⑦ Observe the instructions for use (M002) The warning and information signs comply with ISO 7010; the information in brackets defines the sign according to ISO 7010 Please observe the warning instructions on the packaging and labels. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 92 Risk of motor damage by corrosion resulting from condensation Condensation that does not escape can cause corrosion and motor damage. • Keep the drain holes free so that condensation can escape freely. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 93: Installation

    • Place the unpacked rotor core in a safe place. Secure the rotor core with non-magnetic devices. • Avoid contact of the rotor core with ferromagnetic bodies. • Preferably use tools made of non-magnetic materials. Ferromagnetic assembly tools must have low mass. Work carefully! SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 94 • When transporting or storing permanent-magnet motors always use the original packing materials with the warning labels attached. • Clearly mark the storage locations with the appropriate warning labels. • IATA regulations must be observed when transported by air. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 95 • Do not wear or carry any magnetic or electronic data storage media (e.g. credit cards, USB sticks, floppy disks) and no electronic devices (e.g. watches) if you are close to a rotor! SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 96: Installation And Removal Of The Rotor

    Air-conditioned room or cold chamber for tempering the spindle shaft and rotor core 1) The temperatures for installation can be found in the Table "Installation temperatures" in the associated Hardware Installation Manual. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 97 • Preferably with a device for quick lowering Transport of the heated rotor core Transport of the cooled or tempered spindle shaft depending on size and weight depending on size and weight Figure 7-1 Examples for transporting components SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 98 Stable support with opening ④ Assembly fixture (non-magnetic, resistant to heat and cold, thermally insulating) ⑤ Connecting thread for oil pressure pump for rotor cores with sleeve Figure 7-2 Arrangement for assembling the rotor SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 99 • Pressure oil for relieving stress, e.g. SKF LHMF 300 (viscosity 300 mm²/s at 20° C) • Pressure oil for removal, e.g. SKF LHDF 900 (viscosity 900 mm²/s at 20° C) SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 100 The shrink-fit rotor core must be machined to the external diameter specified in the respective dimension sheet. We recommend machining by grinding. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 101: Installation Overview For Asynchronous Rotors (Brief Description)

    Installation 7.2 Installation and removal of the rotor 7.2.2 Installation overview for asynchronous rotors (brief description) Figure 7-5 Sequence for mounting the rotor in asynchronous version SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 102: Balancing The Asynchronous Version

    The mounting dimensions can be taken from the dimension drawings, see Chapter Dimension drawings for the 1FE2 (https://support.industry.siemens.com/cs/ww/en/view/109783766). A minimum shaft wall thickness is specified in the area of the interference fit. These can be taken from the dimension drawings. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 103: Installation Overview For Synchronous Rotors (Brief Description)

    Installation overview for synchronous rotors (brief description) Figure 7-7 Sequence for mounting the rotor in synchronous version 7.2.5 Balancing the synchronous version On the synchronous version, you balance a rotor with its sleeve. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 104 Motor type Additional minimum possible compensation Number of enclosed bal- of imbalance during fine balancing ) (gmm) ancing weights (Qty.) 1FE2182-8 2200 1FE2183-8 1FE2184-8 1FE2185-8 1FE2186-8 3200 1FE2187-8 ) without rotor SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 105 If you require further balancing weights, you can order these with the article number 340.40002.01 from the Service Center. Note The spindle manufacturer is responsible for selecting and verifying the balancing system. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 106: Removing The Rotor (Brief Description)

    Installation 7.2 Installation and removal of the rotor 7.2.6 Removing the rotor (brief description) Figure 7-10 Procedure for removing the rotor SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 107: Installing The Stator

    Additional installation, production and auxiliary equipment • Hot-air oven with temperature monitoring – Oven volume appropriate for the stator type – Placement of the oven in the immediate vicinity of the workplace SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 108: Installing The Stator (Brief Description)

    Installation 7.3 Installing the stator 7.3.2 Installing the stator (brief description) Figure 7-11 Procedure for mounting the stator SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 109: Installing The Motor Spindle

    Installation 7.4 Installing the motor spindle Installing the motor spindle 7.4.1 Installing the motor spindle (brief description) Figure 7-12 Procedure for installing the motor spindle SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 110: Magnetic Forces That Occur On Synchronous Motors

    The magnitude of the present magnetic forces is motor-specific. Table 7- 4 Magnetic forces that occur in synchronous motors Motor type 16-pole synchronous built-in motors 1FE2182-8L□□□-□□□□ 6000 1FE2183-8L□□□-□□□□ 7500 1FE2184-8L□□□-□□□□ 9000 1FE2185-8L□□□-□□□□ 10500 1FE2186-8L□□□-□□□□ 12000 1FE2187-8L□□□-□□□□ 13500 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 111 (calculated air gap = 0.5 mm). Depending upon the relative position and the weight of the rotor core, an additional axial mounting force of about 300 N is required. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 112 Installation 7.4 Installing the motor spindle SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 113: Connecting

    • Ensure that the cooling water complies with the required cooling water specification. See Chapter "Cooling (Page 60) " • Ensure that cooling water with the required flow volume is available. See rating plate (type plate). SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 114 • Keep the drain holes free so that condensation can escape freely. 3. Check that the drain holes are free so that condensation can escape freely 4. Check the water cooling for leaks ❒ SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 115: Electrical Connection

    The maximum length of the connecting cables is 50 m with and without VPM. 8.2.1.2 Cable cross-section, cable outer diameter and cable variant for asynchronous versions The values specified in the following table refer to the cable outlet of the motor. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 116 Notes on using cables are provided in VDE 0298, Part 3 and Part 4 You configure further connection cables appropriate for the rated current in accordance with EN 60204-1 depending on the routing type and the ambient temperature. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 117 Ground connection for internal and external protective conductors ④ Connectors for temperature sensors Figure 8-1 Terminal boxes with permanent (internal) star connection (example) Note Connect the cables in accordance with project specifications of the spindle manufacturer. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 118: Cable Cross-Section, Cable Outer Diameter And Cable Variant For Synchronous Versions

    For large cable cross-sections, provide an elongated hole as bushing, where necessary. You configure further connection cables appropriate for the rated current in accordance with EN 60204-1 depending on the routing type and the ambient temperature. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 119: Connection Assignment Of The Encoder

    Connect the cables in accordance with project specifications of the spindle manufacturer. 8.2.1.4 Connection assignment of the encoder Note The encoders are not included in the scope of delivery. More detailed information is provided in the SINAMICS documentation. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 120: Terminal Box

    • Ground so there is a good conductive transition between the protective conductor and spindle box protected against corrosion (e.g. bare contact surfaces with a coating of Vaseline). Stator Cooling jacket Spindle housing Bearing shield Ground connection with M8 screw Figure 8-3 Recommended grounding SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 121: High-Voltage Test

    (DC > 820 V) and short-circuits the 3 motor feeder cables. The energy remaining in the motor is converted into heat as a result of the short-circuit and causes the motor to quickly brake. The VPM (Voltage Protection Module) is used as voltage limiter for SINAMICS S120. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 122 No switching elements may be added to the U, V, W connection cables between the drive system, VPM and motor. Connect the VPM with shielded motor supply cables. System requirements: SINAMICS S120 booksize (6SL31xx-xxxxx-xxxx3) SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 123 DC link must have a minimum capacitance. The DC-link minimum capacitance is calculated using the following equation: ∙ 33.33 DClinkmin rated motor / µF DClinkmin rated motor Consider the calculated DC-link capacitance when configuring the system. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 124 VPM cannot be de- 2 x VPM 200 ployed Only those motors that must be operated with VPM are listed in the table. You can use VPM 200 or VPM 200 DYNAMIC. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 125 Connecting 8.2 Electrical connection Wiring diagram Figure 8-4 VPM120 connection diagram SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 126 Connecting 8.2 Electrical connection Figure 8-5 Wiring diagram VPM 200/VPM 200 DYNAMIC SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 127: Version And Operating Modes

    If you connect the associated motor cables of the two partial windings (1U1 and 2U1 → U, 1V1 and 2V1 → V, 1W1 and 2W1 → W), operation with one power section is guaranteed. Note Connect a rotary encoder according to the project specifications. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 128 Signal connector, 17 pin, external thread, Article No.: 6FX2003-0SA17 Optional mounting flange for retrofitting, Article No.: 6FX2003-7DX00 1FE2 built-in motor Ground connection Temperature sensor (+1 Pt1000 spare) Encoder Terminal box Figure 8-6 Circuit diagram for 1FE2 motor with VPM SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 129 Signal connector, 17 pin, external thread, Article No.: 6FX2003-0SA17 Optional mounting flange for retrofitting, Article No.: 6FX2003-7DX00 1FE2 built-in motor Ground connection Temperature sensor (+1 Pt1000 spare) Encoder Terminal box Figure 8-7 Circuit diagram for 1FE2 motor without VPM SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 130 Optional mounting flange for retrofitting, Article No.: 6FX2003-7DX00 1FE2 built-in motor Ground connection Temperature sensor (+1 Pt1000 spare) Encoder Terminal box Figure 8-8 Circuit diagram for 1FE2 motor with VPM via SME120 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 131 Signal connector, 17 pin, external thread, Article No.: 6FX2003-0SA17 Optional mounting flange for retrofitting, Article No.: 6FX2003-7DX00 1FE2 built-in motor Ground connection Temperature sensor (+1 Pt1000 spare) Encoder Terminal box Figure 8-9 Connection overview with OA software and VPM SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 132 Signal connector, 17 pin, external thread, Article No.: 6FX2003-0SA17-..Optional mounting flange for retrofitting, Article No.: 6FX2003-7DX00 1FE2 built-in motor Ground connection Temperature sensor (+1 Pt1000 spare) Encoder Terminal box Figure 8-10 Connection overview with OA software without VPM SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 133 Signal connector, 17 pin, external thread, Article No.: 6FX2003-0SA17 Optional mounting flange for retrofitting, Article No.: 6FX2003-7DX00 1FE2 built-in motor Ground connection Temperature sensor (+1 Pt1000 spare) Encoder Terminal box Figure 8-11 Connection overview with VPM and encoder switch SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 134: Connecting The Asynchronous Version

    • An external contactor circuit The star-delta connection via a fixed setting in the terminal box The standard setting is the star connection via jumpers. Figure 8-12 Fixed star/delta connection in the terminal box SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 135 3. Arrange the jumpers according to the required connection. (see diagram "Fixed star-delta connection in the terminal box") 4. Tighten the screws for the jumpers. 5. Close the terminal box. Ensure that the gasket is in the correct position. ❒ SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 136 • 2 motor contactors with positively driven auxiliary contacts (1 NC contact, 1 NO contact) • 1 motor, 1 control unit, 1 infeed, and 1 Motor Module Figure 8-13 Example of star-delta changeover SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 137 The circuit diagram contains information about wiring and connecting the motor winding. The circuit diagram is provided in the motor packaging. Note Connect a rotary encoder according to the project specifications. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 138 Optional mounting flange for retrofitting, Article No.: 6FX2003-7DX00 1FE2 built-in motor Ground connection Temperature sensor (+1 spare) Encoder Terminal box Figure 8-14 1FE2 asynchronous version connection overview for fixed star connection to SINAMICS SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 139 Optional mounting flange for retrofitting, Article No.: 6FX2003-7DX00 1FE2 built-in motor Ground connection Temperature sensor (+1 spare) Encoder Terminal box Figure 8-15 1FE2 asynchronous version connection overview for star-delta connection via contactors to SINAMICS SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 140: Conversion Of The Converter Setting Data

    The values cannot be parameterized 1:1 for the master-slave operation. They must convert the values to the individual subconverters. The following example shows the conversion procedure. Motor type: 1FE2184-8LH☐☐-☐CC1 : 425 V motor SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 141 Connecting 8.2 Electrical connection Values with rotor sleeve, see 1FE2 Configuration Instructions or customer-specific documenta- tion Figure 8-16 Converter setting data SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 142 'Motor moment of inertia 1.05 0.525 0.525 Parameters(344, 0) 'Motor weight (for thermal motor type) Parameters(348, 0) 'Speed at the start of field weaken- 1440 1440 1440 ing Vdc = 600 V SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 143 Phase for PWM generation Parameters(1980, 0) 'PolID procedure Parameters(1981, 0) 'PolID maximum distance Parameters(1982, 0) 'PolID selection Parameters(1993, 0) 'PolID motion-based current Parameters(1994, 0) 'PolID motion-based rise time Parameters(1995, 0) 'PolID motion-based gain SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 144 In accordance with this parameter list, some reference values must be changed. Note that some converter-specific parameters depend on the encoder or application. If you have questions, please contact the Technical Support. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 145: Technical Data And Characteristics

    The motor powers and torques specified in this documentation refer to the values that the rotor of the built-in motor transfers to the spindle. To calculate the net power output at the shaft, subtract the total friction losses from the specified values. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 146: Technical Data

    2353 1000 4200 ☐CC1 1FE2187-8LN☐☐- 1530 2156 2626 2670 ☐CC1 1FE2187-8LH☐☐- 1510 2151 2618 1000 4200 ☐CC1 The maximum current I must not be exceeded due to the risk of demagnetization SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 147: Technical Data For The Asynchronous Version

    ☐☐☐1 1FE2095-8CG☐☐- 3000 16000 ☐☐☐2 1FE2095-8CG☐☐- 1000 10000 ☐☐☐2 1FE2145-8CC☐☐- 6000 ☐☐☐2 1FE2145-8CC☐☐- 1500 10000 ☐☐☐2 1FE2145-8CE☐☐- 6000 ☐☐☐1 1FE2147-8CC☐☐- 1008 6000 ☐☐☐2 1FE2147-8CC☐☐- 1300 10000 ☐☐☐2 1FE2147-8CE☐☐- 1012 6000 ☐☐☐1 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 148: Characteristics

    Technical data and characteristics 9.3 Characteristics Characteristics The data sheets and characteristics for the various motor frame sizes are available in SIOS under Technical data and characteristics (https://support.industry.siemens.com/cs/ww/de/view/109783767/en). SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 149: Dimension Drawings

    You can find the dimension drawings for the 1FE2 built-in motors under Dimension drawings for the 1FE2 (https://support.industry.siemens.com/cs/ww/en/view/109783766) in SIOS. Note Siemens AG reserves the right to change the motor dimensions as part of design improvements without prior notification. You can also find the dimension drawings for the required motors in: CAD CREATOR (http://www.siemens.com/cadcreator),...
  • Page 150 Dimension drawings SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 151: Environmental Compatibility

    For environmentally-friendly recycling and disposal of your old device, please contact a company certified for the disposal of waste electrical and electronic equipment, and dispose of the old device as prescribed in the respective country of use. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 152 Environmental compatibility SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 153: Technical Data And Dimensions Of The Recommended Series Reactors

    The drive system setting data, as well as the electrical power data, are only applicable in conjunction with these reactors. Note The specified data cannot be guaranteed when using other reactors. SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 154 Appendix A A.1 Technical data and dimensions of the recommended series reactors Technical data and dimensions TEU2731-1UA00-0A Figure A-1 DB_TEU2731-1UA00-0A_75 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 155 Appendix A A.1 Technical data and dimensions of the recommended series reactors Figure A-2 MTZEU001-03-13 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 156 Appendix A A.1 Technical data and dimensions of the recommended series reactors Technical data and dimensions TEU3031-0UA00-0A Figure A-3 DB_TEU3031-0UA00-0A_75 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 157 Appendix A A.1 Technical data and dimensions of the recommended series reactors Figure A-4 MTZEU001-04-13 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 158 Appendix A A.1 Technical data and dimensions of the recommended series reactors SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 159: Index

    Training, 3 Type of construction, 25 Manufacturer declaration, 20 Moments of inertia, 26 Motor spindle, 22, 22 Vibration values, 46 Mounting VPM, 119, 132 Rotor, (Asynchronous motor), (Synchronous motor) Stator, 106 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...
  • Page 160 Index Warning signs, 92 Zero-speed monitoring, 52 SIMOTICS M-1FE2 built-in motors Configuration Manual, 05/2021, A5E50494252B AB...