4.3 Connection on Back Panel

The figure below shows the back panel connection terminals of the camera control unit.

4.4 Connector Pin Assignments

DC IN 12V
1
+12V
2
+12V
3
GND
4
GND
* When using the REMOTE terminal, please consult with your dealer.
Using the auto-iris lens
The following table shows the IRIS terminal when using the auto-iris (EE) lens.
Table 1
IRIS Connector
Terminal No.
The IRIS connector used for the IRIS terminal: HR10A-7P-6P of HIROSE ELECTRIC
CO., LTD.
DC IN 12V
EXT SYNC
1
3
2
4
REMOTE
4
3
5
2
1
9
8
7
6
S-VIDEO
1
GND
2
GND
3
Y
4
C
Signal
1
2
Video signal
3
4
Power (DC)
5
6
S-VIDEO
VIDEO
4
3
2
1
IRIS
FUNC LOCK
6
ON
5
OFF
4
REMOTE
1
NC
2
TXD
3
RXD
4
DSR
5
GND
6
DTR
7
CTS
8
RTS
9
NC
––
GND
+ 12V (less than 50mA)
(GND)
––
1
2
3
IRIS
1
NC
2
VIDEO
3
GND
4
+12V
5
GND
6
NC
Rated
0.8 ± 0.1Vp-p
9