Siemens SINAMICS S120 Device Manual page 210

Cabinet modules nema
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Cabinet Modules
5.5 Booksize format Motor Modules
Order no.
Installation width
SCCR (short circuit current rating)
Rated output of a typ. 6-pole standard induction motor based on I
1)
Rated output of a typ. 6-pole standard induction motor based on I
2)
The base load current I
3)
For a DC link voltage of 600 V DC.
4)
For the interdependency of pulse frequency and max. output current/output frequency, see SINAMICS - Low Voltage
5)
Configuration Manual on the customer DVD supplied with the device.
The specified power loss represents the maximum value at 100 % capacity utilization. The value in normal operation is
6)
lower.
Total of all motor cables. Longer cable lengths for specific configurations are available on request, see SINAMICS - Low
7)
Voltage Configuration Manual on the customer DVD supplied with the device.
210
6SL3720-
inch
mm
kA IC
is based on a duty cycle of 150 % for 60 s or 176 % for 30 s with a duty cycle duration of 300 s.
H
1TE21-0AU3 1TE21-8AU3 1TE23-0AU3 1TE24-5AU3
4
4
100
100
65
65
or I
at 400 V 3 ph. AC 50 Hz.
N
H
or I
at 460 V 3 ph. AC 60 Hz.
N
H
4
8
100
200
65
65
Cabinet Modules NEMA
Manual, 04/2014, A5E03586450A

Advertisement

Table of Contents
loading

Table of Contents