Siemens SIMATIC RTLS System Manual page 175

Hide thumbs Also See for SIMATIC RTLS:
Table of Contents

Advertisement

The equipment also carries the following notes:
XXXYYYZZZ
7.7
SIMATIC RTLS PCB OEM AX
7.7.1
Device description
7.7.1.1
Order data RTLS PCB OEM AX
Table 7-16
SIMATIC RTLS PCB OEM AX
7.7.1.2
Pin assignment
P200 socket
For connecting the HWL scanner
Type: DF40HC(2.5)-20DS-0.4V(51)
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
18
System Manual, 04/2019, C79000-G8976-C577-01
[= serial number, is assigned during production]
Order data RTLS PCB OEM AX
Description / Function
Not used
Grounding
Not used
Not used
Not used
Not used
Not used
Grounding
Not used
RTS
3.4 V scanner operating voltage
CTS
3.4 V scanner operating voltage
TXD
3.4 V scanner operating voltage
RXD
Grounding
Transponder
7.7 SIMATIC RTLS PCB OEM AX
Article number
6GT2700-8DF00-0AX0