Table 2-5
Power cord specifications by country (continued)
Country
Switzerland
Taiwan
UK, Middle East, Hong Kong,
Singapore
USA, Canada, Mexico, Middle East
(optional)
Table 2-6
Appliance coupler (cutter connection), all countries
Appliance coupler (power cable)
Detachable terminal as per IEC60320-1 C13 (squared type)
NOTE:
Place the wall receptacle close enough to the cutter so the plug can be plugged and unplugged easily.

Powerline disturbances

As with all computer and electronic equipment, reliable operation of your cutter depends on the availability of
relatively noise-free AC power.
In order to ensure optimum performance and reliability, your cutter should be protected from variations in
line voltage. Lightning, line faults, or the switching of lighting or machinery can generate line transients that
8
Chapter 2 Site preparation requirements
Length
Plug type
2.5 m
SEV 1011:2009, chapter 6534-2
2.5 m
CNS 690 Type 2(1)
4.5 m
BS 1363/A (13A fused)
2.5 m
NEMA 5-15
Appliance coupler inlet (cutter)
Detachable inlet as per IEC60320-1 C14 (squared type)
Plug