ZONE CONTROLLER
4
h If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
h Means for disconnection must be incorporated in the fixed wiring in accordance with the
wiring rules.
h Qualified service technician is only possible to access to product.
Minimum cross-sectional area of conductors
Rated current of appliance
A
≤0,2
>0,2
and
≤3
>3
and
≤6
>6
and
≤10
>10
and
≤16
>16
and
≤25
>25
and
≤32
>32
and
≤40
>40
and
≤63
a
*
These cords may only be used if their length does not exceed 2 m between the point
where the cord or cord guard enters the appliance and the entry to the plug.
b
Cords having the cross-sectional areas indicated in the parentheses may be used for
portable appliances if their length does not exceed 2 m.
NOTE: For supply cords supplied with multi-phase appliances, the nominal cross-sectional
area of the conductors is based on the maximum cross-sectional area of the conduc-
tors per phase at the supply cord connection to the appliance terminals.
5
Nominal cross-sectional area
mm
2
Tinsel cord
a
a
0,5
0,75
b
1,0 (0,75)
1,5 (1,0)
b
2,5
4
6
10