The parallel connection is limited to a maximum of 2 air-cooled SINAMICS S120 Motor Modules
Booksize.
These Motor Modules must fulfill the following requirements:
● Same frame size:
– 200 A (107 kW) / MLFB: 6SL3120-1TE32-0AAx
● Same firmware version (≥ V5.2)
● Same hardware version (acc. to nameplate)
Note
Replacement in the event of a fault
● Always replace both Motor Modules Booksize when a replacement part is needed.
● Take the hardware version into consideration when replacing a faulty Motor Module
Booksize. Both Motor Modules must have the same hardware version following
replacement.