HP 8572A User Manual page 89

Emi receiver
Hide thumbs Also See for 8572A:
Table of Contents

Advertisement

HP 8572A EMI Receiver User's Guide
All manuals and user guides at all-guides.com
Test Settings
Settings for Amplitude Accy. INPUT 2 (10 dB AT and
Function
Band B (Auto)
RF FREQ
20 MHz to 30 MHz 30 MHz to 300 MHz 300 MHz to 2.0 GHz
QPA lter
RES BW
100 kHz
RFPS (atten)
SA (atten)
10 dB or 0 dB
Scale
Settings for Disp. Average Noise Input 2, 10 Hz RBW
Settings for Residual Responses INPUT 2
0 dB AT)
Band C (Auto)
9 kHz
120 kHz
1 MHz
0 dB
0 dB
10 dB or 0 dB
Linear
Linear
Function
Settings (Auto)
RF FREQ
20 MHz to 2.0 GHz
QPA lter
BYPASS
RES BW
30 kHz
RFPS (atten)
SA (atten)
Scale
Log 10 dB
Function
Settings (Auto)
RF FREQ
20 MHz to 2.0 GHz
QPA lter
BYPASS
RES BW
30 kHz
RFPS (atten)
SA (atten)
Scale
Log 10 dB
Band D (Auto)
120 kHz
1 MHz
0 dB
10 dB or 0 dB
Linear
0 dB
0 dB
0 dB
0 dB
Test Descriptions
3-35

Advertisement

Table of Contents
loading

Table of Contents