Conf" Pushbutton; Led Display - Bosch Rexroth IndraControl XFE01.1-SY-01 Operating Instructions Manual

Module
Hide thumbs Also See for Rexroth IndraControl XFE01.1-SY-01:
Table of Contents

Advertisement

IndraControl XFE01.1-SY-01 Safety Ex-
tension Module

12.2.1 "Conf" pushbutton

Press the "Conf" pushbutton once to confirm the established communication
between the programming system and the Safety extension module upon initial
login. This confirmation ensures that you are only connected to the selected
Safety extension module IndraControl XFE01.1-SY-01 and not accidentally to a
different Safety module.

12.2.2 LED display

The display LED indicates the following:
LED
Color and status
Pwr
Off
Red
Green
Error
Off
Red
Tab. 12-1: LEDs to display operational readiness
LED "Run"
LED "Failure"
(Color and status)
(Color and status)
Off
Off
Off
Green
Red
Off
Red, flashing
Off
Red
Green, flashing
Red
Green
Green
Green
Description
No power supply from the standard control present
Error: The voltage monitoring of the Safety function module
IndraControl XFE01.1-SY-01 switched off the safe logic
voltage
All internal voltages of the Safety extension module
IndraControl XFE01.1-SY-01 are within the permitted range
The Safety extension module IndraControl XFE01.1-SY-01 is
ready
The Safety extension module IndraControl XFE01.1-SY-01 is
not ready. This LED is on during the initialization phase.
If the LED is still on after the initialization (approx. 1 min) or
if the LED is permanently switched on at runtime, integrated
self-tests determined a "fatal error" (e.g. hardware error).
The Safety extension module IndraControl XFE01.1-SY-01 is
then probably defective and has to be replaced.
Contact the Bosch Rexroth Service
Operating state of the Safety extension module IndraControl
XFE01.1-SY-01
No power supply provided or hardware reset triggered
Initialization phase; first part (ca. 30 s) is running
Initialization phase; second part (ca. 10 s) is running
Ready for download.
The Safety extension module IndraControl XFE01.1-SY-01
does not contain any valid application or a download is not
yet completed
Request to press the "Conf" pushbutton
SAFETY STOP
SAFETY RUN
R911376654_Edition 03 Bosch Rexroth AG
33/45
Device description

Advertisement

Table of Contents
loading

Table of Contents