Download Print this page
Toshiba RBC-AMT31E Owner's Manual

Toshiba RBC-AMT31E Owner's Manual

Wired standard remote controller
Hide thumbs Also See for RBC-AMT31E:

Advertisement

Quick Links

WIRED STANDARD REMOTE CONTROLLER
RBC-AMT31E
Object Indoor Unit
Super Modular Multi System/
Super Heat Recovery System
<4-way Air Discharge Cassette Type>
MMU-AP0091H, AP0121H, AP0151H, AP0181H, AP0241H,
MMU-AP0271H, AP0301H, AP0361H, AP0481H, AP0561H
<2-way Air Discharge Cassette Type>
MMU-AP0071WH, AP0091WH, AP0121WH, AP0151WH, AP0181WH, AP0241WH, AP0271WH,
MMU-AP0301WH
<1-way Air Discharge Cassette Type>
MMU-AP0071YH, AP0091YH, AP0121YH, AP0151SH, AP0181SH, AP0241SH
<Concealed Duct Standard Type>
MMD-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH, AP0271BH,
MMD-AP0301BH, AP0361BH, AP0481BH, AP0561BH
<Concealed Duct High Static Pressure Type>
MMD-AP0181H, AP0241H, AP0271H, AP0361H, AP0481H, AP0721H, AP0961H
<Under Ceiling Type>
MMC-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H
<High Wall Type>
MMK-AP0071H, AP0072H, AP0091H, AP0092H, AP0121H, AP0122H, AP0151H, AP0181H, AP0241H
<Floor Standing Cabinet Type>
MML-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241H
<Floor Standing Concealed Type>
MML-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH
<Floor Standing Type>
MMF-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H, AP0561H
Digital Inverter Air Conditioner
<4-way Air Discharge Cassette Type>
RAV-SM560UT-E, SM800UT-E, SM1100UT-E, SM1400UT-E
RAV-SP1100UT-E
(Super Digital Inverter)
<Under Ceiling Type>
RAV-SM561CT-E, SM801CT-E, SM1101CT-E, SM1401CT-E
<Concealed Duct High Static Pressure Type>
RAV-SM561BT-E, SM801BT-E, SM1101BT-E, SM1401BT-E
OWNER’S MANUAL
MANUEL DU PROPRIETAIRE
BETRIEBSANLEITUNG
MANUALE DEL PROPRIETARIO
MANUAL DEL PROPIETARIO
MANUAL DO UTILIZADOR
GEBRUIKSAANWIJZING
ÏÄÇÃÉÅÓ ×ÑÇÓÇÓ
MMU-AP0481WH
For commercial use
Pour usage commercial
Nur für gewerbliche Nutzung
Per uso commerciale
Para uso comercial
Para uso comercial
Voor commercieel gebruik
Ãéá åìðïñéêÞ ÷ñÞóç
(CHINA market only)
SET
DATA
SETTING
TEST
UNIT No.
R.C.
No.
H
TEMP.
ON / OFF
CODE No.

Advertisement

loading

Summary of Contents for Toshiba RBC-AMT31E

  • Page 1 BETRIEBSANLEITUNG MANUALE DEL PROPRIETARIO MANUAL DEL PROPIETARIO MANUAL DO UTILIZADOR GEBRUIKSAANWIJZING ÏÄÇÃÉÅÓ ×ÑÇÓÇÓ WIRED STANDARD REMOTE CONTROLLER RBC-AMT31E For commercial use Pour usage commercial Nur für gewerbliche Nutzung Object Indoor Unit Per uso commerciale Para uso comercial Super Modular Multi System/...
  • Page 2 Will eine andere Person die Fernbedienung benutzen, händigen Sie ihr das Handbuch aus. AVVERTENZA • Prima di usare il telecomando (RBC-AMT31E), raccomandiamo la lettura di questo manuale d’istruzioni destinato al proprietario. • Solo per l’installazione del telecomando, non per il funzionamento, fare riferimento al manuale di installazione fornito con il condizionatore d’aria.
  • Page 3 CONTENTS SAFETY CAUTION ............1 ADJUSTMENT OF WIND DIRECTION ......6 PARTS NAME OF REMOTE CONTROLLER ....2 MAINTENANCE ............10 CORRECT USAGE ............4 TROUBLESHOOTING ..........11 TIMER OPERATION ............5 SOMMAIRE MESURES DE SECURITE ........... 12 REGLAGE DU SENS DE SOUFFLAGE ....... 17 NOM DES PIECES DE LA TELECOMMANDE ....
  • Page 4 SAFETY CAUTION • Please read this “Safety Cautions” thoroughly before installation to install the air conditioner correctly. • The important contents concerned to the safety are described in the “Safety Cautions”. Be sure to keep them. For Indications and their meanings, see the following description. n Explanation of indications WARNING Indicates possibilities that a death or serious injury of personnel is caused by an incorrect handling.
  • Page 5 PARTS NAME OF REMOTE CONTROLLER Display section CODE No. In the display example, all indicators are displayed for the explanation. DATA SETTING TEST Display UNIT No. section In reality only, the selected contents are indicated. R.C. • When turning on the leak breaker at the first time, [SET DATA] flashes on TEMP.
  • Page 6 Operation section Push each button to select a desired operation. This remote controller can operate the maximum 8 indoor units. • The details of the operation needs to be set up once, afterward, the air conditioner can be used by pushing ON / OFF button only.
  • Page 7 CORRECT USAGE When you use the air conditioner for the first time or when you change the SET DATA value, follow the proce- dure below. From the next time, the operation displayed on the remote controller will start by pushing the ON / OFF button only.
  • Page 8 TIMER OPERATION A type of timer operation can be selected from the following three types. OFF timer : The operation stops when the time of timer has reached the set time. Repeat OFF timer : Every time, the operation stops after the set time has passed. ON timer : The operation starts when the time of timer has reached the set time.
  • Page 9 ADJUSTMENT OF WIND DIRECTION To increase the cooling or heating effect, be sure to use the discharge flap in the different directions in cooling or heating operation. As the characteristics of the air, the cold air accumulates at lower side and hot air at upper side, respectively. CAUTION Set the louver horizontally in cooling operation.
  • Page 10 How to set up the air direction SWING/FIX Push button. Every pushing the button, the air direction changes. In Heating operation Set the air outlet flap downward. If directing it upward, the hot air may not come to the foot. Initial setup In Cooling / Dry operation Set the air outlet flap upward.
  • Page 11 According to the shape or arrangement of the room, the cold air and hot air can be discharged for two direc- tions or three directions. For details, contact the dealer. INFORMATION • If cooling operation is performed with downward discharge, dew may fall on surface of the cabinet or the horizontal flap resulted in dripping.
  • Page 12 Right/Left air direction adjustment To change the air outlet direction to right or left side, set the vertical flap inside of the horizontal flap to the desired direction. INFORMATION • If cooling operation is performed with downward discharge, dew may fall on surface of the cabinet or the horizontal flap resulted in dripping.
  • Page 13 Floor Standing Type Adjustment of air direction upward/downward [In Cooling operation] In cooling operation, move the flap with hands and use it with horizontal air outlet point so that the cold air diffuses in whole room. [In Heating operation (For Heat-pump model only)] In heating operation, move the flap with hands and use the horizontal flap with downward set point so that the hot air blows at the foot.
  • Page 14 TROUBLESHOOTING Confirmation and check When a trouble occurred in the air conditioner, the CODE No. check code and the indoor unit No. appear on the display part of the remote controller. UNIT No. The check code is only displayed during the opera- R.C.
  • Page 15 EH99923001...