SM 25B Sound Management Alarm Routing Module LBB 2540/10 Philips Communication, Security and Imaging...
Page 2
Installation Instructions ............................5 Instructions d’installation..........................13 Installationsanleitung............................22 Instalación de uso...............................30 Installatievoorschrift ............................39 Istruzioni per d’installazione ..........................47...
Page 3
IMPORTANT SAFEGUARDS 1. Read Instructions - All the safety and operating instructions should be read before the unit is operated. 2. Retain Instructions - The safety and operating instructions should be retained for future ref- erence. 3. Heed Warnings - All warnings on the unit and in the operating instructions should be adhered to.
Page 4
17. Damage Requiring Service - Unplug the unit from the outlet and refer servicing to qualified service personnel under the following conditions: a. When the power-supply cord or plug is damaged. b. If liquid has been spilled, or objects have fallen into the unit. If the unit has been exposed to rain or water.
Page 5
SAFETY PRECAUTIONS COVER REMOVAL WARNING: REMOVAL OF THE COVER SHOULD ONLY BE PER- FORMED BY QUALIFIED SERVICE PERSONNEL - NOT USER SER- VICEABLE. THE UNIT SHOULD CAUTION: TO REDUCE THE RISK ALWAYS BE UNPLUGGED OF ELECTRIC SHOCK, DO NOT BEFORE REMOVING THE COVER, OPEN COVERS.
Page 6
List of abbreviations used in this Installation Instructions Description Type number Alarm Routing Module LBB 2540/00 60 W Booster Amplifier LBB 2106/00 B120 120 W Booster Amplifier LBB 2112/00 B240 240 W Booster Amplifier LBB 2124/00 Booster Connection Board LBB 2503/00 Background Music Blank Panel set LBC 1502/00...
CONTENTS Installation 1.1 Mounting the ARM..........................8 - Introduction ............................8 - Installing the ARM in a Booster Frame...................9 1.2 Connecting the ARM ........................9 - Connecting alarm and time signal inputs ..................10 1.3 Configuring the ARM ........................10 - ARM configuration switches ......................10 1.4 Trouble-shooting the ARM .......................12 WARNING: READ THE IMPORTANT SAFETY INSTRUCTIONS BEFORE INSTALLING THIS EQUIPMENT.
Mounting the Alarm Routing Module (ARM) Introduction The Alarm Routing Module (ARM) is for use in the SM 25B Booster Frames or Module Exten- sion Frame (MXF). It is an alarm signal and time signal generating module for public address applications.
Caution: The ARM is designed to operate safely in a SM 25B Booster Frame or MXF. Ensure that the Booster Frame or MXF is installed in accordance with the Installation Instructions supplied with the equipment before installing the ARM. Supplied with the ARM (LBB 2540/10): • Installation Instructions •...
Connecting alarm and time signal inputs The alarm and time signal switches are connected across poles 4 and 5 of the 5-pole DIN con- nectors. The alarm signal will be activated by opening or closing the switch (depending on the normally closed/normally open setting described in section 1.3).
Page 11
The following is a description of the configuration possibilities of the ARM. Refer to the table earlier in this section for a listing of the DIL switches. Note: Changes in configuration setting only take place after the system has been reset by switching it off and on again, or by pressing the reset button (switch 6, S304, figure 1.19).
To select all call for time signals, and zone selection for alarm signals: • Set switch 8 on DIL switch (S301) to 'OFF' Zone selection To select any combination of zones 1 to 8: • Set the corresponding switches 1 to 8 on DIL switch (S302) to 'ON' To select any combination of zones 9 to 12: •...
Page 14
1.12 1.13 1. N/C 2. N/C 3. N/C 4. Remote Contact 5. Remote Contact 1. N/C 4. Remote Alarm Contact 2. N/C 5. Remote Alarm Contact 3. N/C 1.14 1.15 1.16 Switch Switch Signal Signal Fixed time Fixed time On/Off activation with key released alarm signals On/Off activation with fixed time alarm and time signals 1.17 1.18...