■Drive unit
When an alarm occurs on the drive unit, the status becomes servo-off, but the main circuit power supply is not shut off, so
shut off the main circuit power supply using an external sequence. After canceling the alarm on the drive unit, the operation is
enabled again by turning on the error reset command from the controller.
Converter unit control circuit
power supply
Main circuit power supply
Converter unit alarm
Drive unit
Control circuit power supply
Base circuit
Servo-on command
(From the controller)
Drive unit
Alarm
Reset command
(From the controller)
Transition No.
1) in the figure
2) in the figure
5 SIGNALS AND WIRING
54
5.5 Timing chart at alarm occurrence
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
No alarm
1.5 s
ON
OFF
Description
If an alarm occurs on the drive unit, shut off the main circuit power supply by using an external sequence.
Turn on the main circuit power supply while the alarm on the drive unit is deactivated.
1)
No alarm
(3 s)
Alarm
Alarm occurrence
2)
(3 s)
No alarm