Access Controllers
2
ACC-AP

2.3.4 Extension Interfaces

2.3.4.1 Extension Option

2.3.4.2 Aperio Wireless Doors Extension Option

2.3.5 Power Monitoring Limits

2.3.6 Factory Reset Button

24 | 38
Label on AP Controller
COMMS1
COMMS2
Label on AP Controller
COMMS1A
COMMS1B
COMMS2
AP Vout-
AP Vout+ (or READER1,2+)
For further details, refer to the section about Aperio setup in this document.
The AP Controller should be provided with power in the range of: 12V – 24V
DC. The AP Power Supply must be protected by a fuse (2A).
An Audit Trail Message will be produced if the voltage level drops below 10.5V
or goes above 26.5V.
Absolute maximum power ratings are: 9.5V – 29.5V DC.
The Reader Power Supply outputs are protected by a thermal fuse. In the
event of a short-circuit the fuse will trip. The fuse will automatically reset in
about 30 seconds if the fault has cleared.
To set the IP Network Settings of the AP Controller back to its default values, hold
the Factory Reset Button down for 10 seconds during standard operation. (See
image in section Updating the AP Controller with Micro SD Card [➙ 25]).
SiPass Point Function
FLN 2
for MFI*, IAT and I/O devices (8IO, IPM, OPM)
*See section Multi-Function Interface (MFI) [➙ 35]
for more information.
Not Used
SiPass Point Function
AH30 RS485 Data A
AH30 RS485 Data B
Not Used
AH30 GND
AH30 PWR 8-24V
A6V11164550