Clock Transfer Cable - Huawei SmartAX MA5600T Hardware Description

Multiservice access module
Hide thumbs Also See for SmartAX MA5600T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Hardware Description
Specification
Type
Characteristic impedance
Diameter of the cable
Diameter of the inner conductor
DC resistance of the inner
conductor
Frequency attenuation
Capacitance

5.4.3 Clock Transfer Cable

The clock transfer cable is a 120-ohm-to-75-ohm clock cable and is used for transmitting
clock/time signals.
Connection
The clock transfer cable is connected as follows:
l
l
Cable Connector
Issue 24 (2018-07-30)
One end of the cable is an RJ45 connector connecting to the CLK/TOD port on the
control board.
The other end is connected to the external clock device. The connector must be made
based on the on-site situation.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Description
Symmetric twisted pair cable-120 ohms-two
pairs-0.40 mm-shielded
120.0 ohm
4.60 mm
0.40 mm
145.0 ohm
2.8 dB/100 m @1.024 MHz
56 nF/km
5 Cable