  • Page 1 Monocrystalline Solar Module LGXXXS1C(W, K)-G3...
  • Page 2: Revisions Table

    Revisions Table Date Version Amendments Tech note 2012.08.01 1.0 (1 edition) Establish 2012.11.16 2.0 (2 edition) Legality check...
  • Page 3 Safety The instructions related to safety and use indicated in ⑥ Do not scratch the coating surface of the frame. the this installation manual are intended for the Scratches may decrease the total solar output due to prevention of unexpected danger, damage, or failure. corrosion of the frame.
  • Page 4: Before & After Installation

    Before & After Installation Before Installation • Dirt build-up on the surface of the panel may cause Please carefully read this manual before installation. active solar cells to be shaded and electrical • Contact with electrically active parts of the panels, performance to be impaired.
  • Page 5: Electrical Installation

    Diodes the protection of the module and cables from over- • All LG modules are equipped with factory installed current and/or blocking diodes for prevention of bypass diodes. The factory-installed diodes provide unbalanced string voltage.
  • Page 6 Electrical Installation General Wiring • LG Electronics recommends that all wiring be double insulated with a minimum rating of 90°C (194°F). • All wiring should use a flexible copper (Cu) conductor. • The minimum size should be determined by the applicable codes.
  • Page 7: Mechanical Installation

    Module frame 50lb/ft2 (about 2400 Pa). Excluded Operating Environments Bolt • The solar modules from LG Electronics can not be Flat washer operated in a location where they could come in direct or indirect contact with salt water or ammonia.
  • Page 8 Mechanical Installation LGXXXS1C(W,K)-G3 Use four mounting holes on two opposite sides. Clamping Range (230mm) 270mm 270mm Use four clamps on the long frame. This method is not tested by IEC / UL. Center ± 100mm Clamping Range: Clamping Range: From module Edge From module Edge to 120mm to 270mm...
  • Page 9: Product Specifications

    Product Specifications - Electrical and Mechanical Properties (Rated electrical characteristics are within 10 percent) Standard Test Condition(STC) : Irradiation 1,000W/m , Cell temp. 25℃, 1.5AM Certifi Electrical Properties Mechanical Properties Other cates LG240S1C-G3 37.96 8.42 30.37 7.91 46.0+2 -0.420 <4.5 1640 1000 16.8...
  • Page 10: Disclaimer Of Liability / Disposal

    LG its affiliated companies, successors, or assigns, its administrators, directors, agents, officers, volunteer and employees.
  • Page 11 Contact : lg.solar@lge.com http://www.lgsolarusa.com This document is subject to change without notice. LG, LG logo and Life's Good are trademarks of LG Electronics, Inc. worldwide. Trademarks and intellectual properties of LG Electronics, Inc. are protected by international copyright laws. Document : II-G3-UL-V2-EN-201211...