Description of the device
RJ-45 jacks
The connection of the communications processor 1626 to the LAN (local area network) is via
one of the four RJ-45 jacks on the front panel of the communications processor.
In each case, 2 jacks are connected to the integrated real-time switch.
Jacks 1 and 2 are intended for IO device operation.
Jacks 3 and 4 allow IO controller and/or IO device operation.
Note
For the "network separation" property, use sockets 1 and 2 for one IP subnet and sockets 3
and 4 for the other IP subnet.
CP 1626 in a PC as IO controller
The following figure shows a typical application:
PC with CP 1626 as PROFINET IO controller at the IO controller level.
The IO-Base controller user program runs on the PC and accesses the functions of the IO-
Base user programming interface.
The data traffic is handled via a CP 1626 with several SIMATIC S7 PROFINET IO devices
ET 200S via Industrial Ethernet.
14
Operating Instructions, 11/2018, C79000-G8976-C434-03