Download Print this page

Toro 2024 Directional Drill Software Manual page 15

Hide thumbs Also See for 2024 Directional Drill:

Advertisement

Cam Arm I/O Screen
To access this screen push button 3 on the I/O screen.
Use this screen to adjust the cam calibration options.
Push the up and down buttons to select the load
position and the pipe-row position.
The voltage on the bottom indicates the cam raw
sensor voltage. The voltages range from 1.0 to 4.0 V.
Any voltage higher or lower indicates either sensor
failure or incorrect calibration.
The other voltages are calibrated voltages.
Push button 3 to toggle the calibration on and off.
Push the OK button 3 times on the desired row to
save the calibration.
Figure 56
Auxiliary I/O Screen
To access this screen push button 5 on the I/O screen.
All icons change from black to green when you
operate the associated functions.
g204520
1. Raise/Lower elevator
2. Breakout wrench
3. Vise
4. Gripper
The breakout wrench icon will show arrows above the
icon to indicate when the rotating wrench is open or
closed.
15
Figure 57
5. Arm extension/retract
sensor
6. Rotate pipe cam
7. TJC grease
g207493

Advertisement

loading

This manual is also suitable for:

2380023800a23800c23800te23800w