2. Activation.
The steps of this activation must be followed to avoid damage to the equipment.
Before Turn-On, Check if all on/off key
1
st
Drawers it's "off"
2
nd
Trigger the circuit breaker on (01)
MC8001 Display - Second Home Screen (Status)
02
03
Switch On the two Power Supplies (04) in the
7
th
MOD GV 40226 Drawer
Check the Drawer Communication Status.
In the Main Module Control Display Interface:
>Measurements [2000] > Communications
8
th
Status [2500]
Pxx = OK
Check the ALL Power Supply and Current when
0 (Zero) Watts Transmitter FWD Power:
In the Main Module Control Display Interface:
>Measurements [2000] > Drawers [2300]
> Power Supply [2310]
9
th
Power Supply ≈ 45,5V
>Measurements [2000] > Drawers [2300]
> Current [2320]
I ≈ 0,30A (for each PA)
E-Compact Medium Power
01
Check if both the Exciter (Main and Backup) are
3
rd
configured for the correct channel, the same as
the Mask Filter and the Antenna.
Check if both the Module Control CM8001 (Main
and Backup):
4
th
Chanel is the same of the Exciter (02)
The description of the Equipment is correct (03)
Check if the Main Exciter and Main Module
5
th
Control CM8001 are active.
Check if the Programmed Power in Main
Module Control CM8001 is 0 (ZERO) Watts:
6
th
Display Interface
>Measurements [2000] > Power [2100] >
Programmed Power [1/3]
04